Samsung AR18NVFHEWKXMG, AR24NVFHEWKXMG, AR24NSFHEWKNMG manual For Power Supply

Page 5

CAUTION

Install your appliance on a level and hard floor that can support its weight.

• Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the drain hose properly so that water drains correctly.

Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste pipes as odours may arise in the future.

When installing the outdoor unit, make sure to connect the drain hose so that draining is performed correctly.

The water generated during heating by the outdoor unit may overflow and result in property damage.

In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

FOR POWER SUPPLY

WARNING

When the circuit breaker is damaged, contact your nearest service centre.

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.

• This may result in electric shock or fire.

CAUTION

When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.

• Failing to do so may result in electric shock or fire.

FOR USING

WARNING

If the appliance is flooded, please contact your nearest service centre.

• Failing to do so may result in electric shock or fire.

If the appliance generates a strange noise, a burning smell or smoke, cut off the power supply immediately and contact the nearest service centre.

• Failing to do so may result in electric shock or fire.

In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line.

Do not use a ventilating fan.

A spark may result in an explosion or fire.

To reinstall the air conditioner, please contact your nearest service centre.

• Failing to do so may result in problems with the product, water leakage, electric shock, or fire.

Safety Information

English 5

Image 5
Contents Air conditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourselfDo not operate the appliance with wet hands Operation indicator Timer indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Horizontal air flow manual Controlling fan speedControlling air flow direction Step cooling function Cool modeCooling Operation Dehumidifying Operation Dry modeHeating Operation Heat modeFan mode Quick Smart FeaturesAuto mode Comfort function Fast functionBeep sound function Quiet functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Replace the batteries in the remote control with new ones Problem Solution Cannot change the fanDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyModel Technical Specifications27˚C 29˚C 20˚C General information Installation of the unitInstallation manual Power supply line, fuse, or circuit breakerInstall the unit in a place where water can drain smoothly Cases Choosing the installation locationMinimum clearances for the outdoor unit Unit mm Packing and UnpackingIndoor unit Outdoor unitOptional accessories AccessoriesAccessories in the indoor unit package Tools Accessories in the outdoor unit packageDrilling a hole through the wall Taping the pipes, cables, and drain hose Indoor Unit Installation Apply heat to the contraction tube to contract it Optional Extending the power cablePrepare the following tools Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame Fixing the installation plateWhen fixing the indoor unit on a wall Fix the installation plate without inclining to one side When fixing the indoor unit on a gypsum boardOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationRefrigerant pipes Cooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Refrigerant Adding refrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode LED Off, Blinking, OnPumping down for removing the product Performing final check and trial operationQuestions or COMMENTS?