Samsung AR24NVFHEWKXMG, AR24NSFHEWKNMG manual Installing and connecting the drain hose, Or a fire

Page 36

Installation

WARNING

In case of extending the electric wire, please DO NOT use a round-shaped

pressing socket.

–– Incomplete wire connections can cause electric shock

or a fire.

Step 2.3 Installing and connecting the drain hose

1Install the drain hose.

Drain hose

Assembly pipe

Connection hose

Wall

 

 

Indoor unit

 

 

Drain hose

 

Water

 

 

Slant downwards

Slant upwards

Dipped in water

 

 

5 cm

 

 

less

Bent

Too small

Ditch

Too small

 

clearance

clearance

2Pour water into the drain pan. Check whether the hose is well drained.

CAUTION

Make sure that the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Inadequate installation may cause water leakage.

If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

Do not box in or cover the drain hose connection. Drain hose connection must be easily accessible and serviceable.

Step 2.4 Optional: Extending the drain hose

Drain hose (A) Extension drain hose (B)

(A)(B)

Drain hose

Extension drain hose

20 mm or more Foam insulation

Vinyl tape

36English

Image 36
Contents Air conditioner Contents Correct disposal of batteries in this product Safety Information Failing to do so may result in electric shock or fireThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not clean the inside of the air conditioner by yourself Do not operate the appliance with wet handsDo not drink the water from the air conditioner Timer indicator Operation indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionHorizontal air flow manual Cool mode Cooling OperationStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationQuick Smart Features Auto modeFan mode Fast function Comfort functionQuiet function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Problem Solution Cannot change the fan Replace the batteries in the remote control with new onesDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyTechnical Specifications Model27˚C 29˚C 20˚C Installation of the unit General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyInstallation manual Choosing the installation location Minimum clearances for the outdoor unitCases Packing and Unpacking Unit mmIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools Taping the pipes, cables, and drain hose Indoor Unit Installation Optional Extending the power cable Prepare the following toolsApply heat to the contraction tube to contract it Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one sideOutdoor Unit Installation Refrigerant pipesOptional Fixing the outdoor unit to a wall with a rack Leave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Adding refrigerant RefrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests Off, Blinking, On LEDPerforming final check and trial operation Pumping down for removing the productQuestions or COMMENTS?