Samsung AR24NVFHEWKXMG, AR24NSFHEWKNMG, AR18NVFHEWKXMG manual Off, Blinking, On, Led

Page 45

When error occurs, take necessary measures by referring to the following table. For more information on necessary measures for errors, refer to the service manual.

 

Error indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Display

Error

Measures for the installer to take

 

 

 

 

 

 

Display

 

LED 1

LED 2

 

LED 3

 

 

 

 

 

 

 

 

 

/

 

 

 

 

 

 

 

 

Communication error

• Check the connection wire between the

 

 

 

 

 

 

between indoor and

indoor and outdoor units (whether the

 

 

 

 

 

 

outdoor units

power cable or communication cable is

 

 

 

 

 

 

 

crossed or not).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error on indoor

• Check the connection of the connector.

 

 

 

 

 

 

temperature sensor

 

 

 

 

 

 

 

 

 

,

 

 

 

 

 

Error on indoor heat

• Check the connection of the connector.

 

 

 

 

 

exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error on indoor fan

• Check the connection of the connector.

 

 

 

 

 

 

motor

• Remove foreign substance. (Check for the

 

 

 

 

 

 

 

cause that restrains motor.)

 

 

 

 

 

 

 

 

display and

 

 

 

 

 

EEPROM/Option

Re-set options.

all LEDs blink.

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant flow

• Check if the stop valve is completely open.

 

 

 

 

 

 

blocking error

• Check if there is any blockage in the

 

 

 

 

 

 

 

refrigerant pipe which connects the indoor

 

 

 

 

 

 

 

and outdoor units.

 

 

 

 

 

 

 

• Check for refrigerant leak.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lack of refrigerant

• Check if a sufficient amount of refrigerant

 

 

 

 

 

 

(for inverter models

is additionally charged for the pipe

 

 

This LED pattern

only)

longer than specified in piping codes and

 

 

 

standards.

 

 

appears when an

 

• Check for refrigerant leak between valve

 

 

error occurs on the

 

 

 

 

and pipe connection.

 

 

outdoor unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Off, : Blinking, : On

Installation

English 45

Image 45
Contents Air conditioner Contents Correct disposal of batteries in this product Safety Information Failing to do so may result in electric shock or fireThis may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not clean the inside of the air conditioner by yourself Do not operate the appliance with wet handsDo not drink the water from the air conditioner Operation indicator Timer indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionHorizontal air flow manual Cool mode Cooling OperationStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeQuick Smart Features Auto modeFan mode Comfort function Fast functionBeep sound function Quiet functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Running Auto clean Cleaning at a GlanceCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Replace the batteries in the remote control with new ones Problem Solution Cannot change the fanDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyModel Technical Specifications27˚C 29˚C 20˚C General information Installation of the unitPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyInstallation manual Choosing the installation location Minimum clearances for the outdoor unitCases Unit mm Packing and UnpackingIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools Taping the pipes, cables, and drain hose Indoor Unit Installation Optional Extending the power cable Prepare the following toolsApply heat to the contraction tube to contract it Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side When fixing the indoor unit on a gypsum boardOutdoor Unit Installation Refrigerant pipesOptional Fixing the outdoor unit to a wall with a rack Leave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Refrigerant Adding refrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests LED Off, Blinking, OnPumping down for removing the product Performing final check and trial operationQuestions or COMMENTS?
Related manuals
Manual 48 pages 7.93 Kb