this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and will be charged to end user.

When installing the outdoor unit at the seaside, make sure that it is not directly exposed to sea breeze. If you cannot find an adequate place free from direct sea breeze, construct a protection wall or a protective fence.

–– Install the outdoor unit in a place (such as near buildings etc.) where it can be protected from sea breeze. Failure to do so may cause a damage to the outdoor unit.

 

Sea breeze

 

Sea breeze

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sea

 

 

Outdoor unit

Sea

 

 

Outdoor unit

If you cannot avoid installing the outdoor unit at the seaside, construct a protection wall around to block the sea breeze.

Construct a protection wall with a solid material such as concrete to block the sea breeze. Make sure that the height and the width of the wall are 1.5 times larger than the size of the outdoor unit. Also, secure a space larger than 600 mm between the protection wall and the outdoor unit for exhausted air to ventilate.

Sea breeze Protection wall

Outdoor unit

Sea

Outdoor unit

Protection wall

 

Install the unit in a place where water can drain smoothly.

If you have any difficulty finding installation location as prescribed above, contact your manufacturer for details.

Be sure to clean the sea water and the dust on the heat exchanger of the outdoor unit and apply a corrosion inhibitor on it. (At least once in a year.)

Power supply line, fuse, or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.

Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

Always verify that the cut-off and protection switches are suitably dimensioned.

Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Be sure not to perform power cable modification, extension wiring, and multiple wire connection.

–– It may cause electric shock or fire due to poor connection, poor insulation, or current limit override.

–– When extension wiring is required due to power line damage, refer to "Step 2.2 Optional:Extending the power cable" in the

installation manual.

28English

Image 28
Contents Air conditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not clean the inside of the air conditioner by yourselfDo not drink the water from the air conditioner Timer indicator Operation indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort functionQuiet function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Problem Solution Cannot change the fan Replace the batteries in the remote control with new onesDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyTechnical Specifications Model27˚C 29˚C 20˚C Installation of the unit General informationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerInstallation manual Minimum clearances for the outdoor unit Choosing the installation locationCases Packing and Unpacking Unit mmIndoor unit Outdoor unitAccessories in the indoor unit package AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Indoor Unit Installation Prepare the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one sideRefrigerant pipes Outdoor Unit InstallationOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant RefrigerantRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Off, Blinking, On LEDPerforming final check and trial operation Pumping down for removing the productQuestions or COMMENTS?