Samsung AR18NVFHEWKXMG Drilling a hole through the wall, Accessories in the outdoor unit package

Page 32

Installation

Accessories in the outdoor unit package

Rubber leg (4)

NOTE

A flare nut is attached to the end of each pipe of an evaporator or a service port. Use flare nuts when connecting the pipes.

Wire assembly cables are optional. If they are not supplied, use standard cables.

The drain plug and the rubber legs are included only when the air conditioner is supplied without assembly pipes.

If these accessories are supplied, they are in the accessory package or outdoor unit package.

Tools

General tools

Vacuum pump

(Backward flowing prevention)

Manifold gauge

Stud finder

Torque wrench

Pipe cutter

Reamer

Pipe bender

Spirit level

Screwdriver

Spanner

Drill

L-wrench

Measuring tape

Tools for test operation

Thermometer

Resistance meter

Electroscope

Step 1.4 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left Right

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

<Minimum distances between the hole and the installation plate>

(Unit : mm)

Model

A

B

C

D

 

 

 

 

 

✴✴18✴✴T✴✴✴✴

38

126

70

38

✴✴24✴✴T✴✴✴✴

 

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

32English

Image 32
Contents Air conditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourselfDo not operate the appliance with wet hands Timer indicator Operation indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesOperation modes Remote Control OperationControlling temperature Horizontal air flow manual Controlling fan speedControlling air flow direction Step cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationHeat mode Heating OperationFan mode Quick Smart FeaturesAuto mode Fast function Comfort functionQuiet function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Problem Solution Cannot change the fan Replace the batteries in the remote control with new onesDoes not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyTechnical Specifications Model27˚C 29˚C 20˚C Installation of the unit General informationInstallation manual Power supply line, fuse, or circuit breakerInstall the unit in a place where water can drain smoothly Cases Choosing the installation location Minimum clearances for the outdoor unit Packing and Unpacking Unit mmIndoor unit Outdoor unitOptional accessories AccessoriesAccessories in the indoor unit package Tools Accessories in the outdoor unit packageDrilling a hole through the wall Taping the pipes, cables, and drain hose Indoor Unit Installation Apply heat to the contraction tube to contract it Optional Extending the power cablePrepare the following tools Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose Or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one sideOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationRefrigerant pipes Cooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Adding refrigerant RefrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Off, Blinking, On LEDPerforming final check and trial operation Pumping down for removing the productQuestions or COMMENTS?