Samsung SDM-160N manual Recording, Normal record mode, Time Lapse record mode

Page 34

Digital Multiplexer

Chapter 6. Recording

1. Normal record mode

When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to “NOR”.

(1)Frame record

-When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to FRAME.

-The image signal entered from the maximum 16 cameras is output in Frame and recorded on the VCR.

-The recorded output records the only channel that the “REC DUTY” of the “1.REC OUT SET” is set to more than 1.

1/30sec(NTSC), 1/25(PAL)

(2)Field record

-When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to “FIELD”.

-The image signal entered from the maximum 16 cameras is output in Field and recorded on the VCR.

-The recorded output records the only channel that the “REC DUTY” of the “1.REC OUT SET” is set to more than 1.

1/60sec(NTSC), 1/50(PAL)

2.TIME LAPSE record mode

-When setting the “REC TYPE” of the setup menu “1.REC OUT SET” to “TLV”.

-The image signal entered from the maximum 16 cameras is recorded on the VCR in response to the trigger signal of VCR.

-The recorded output records the only channel that the “REC DUTY” of the “1.REC OUT SET” is set to more than 1.

-The trigger out of VCR and the VTR terminal this unit must be connected.

-“NO TRIGGER” character is displayed on screen while operating the field record operation of the normal mode if the trigger signal is not received for 10 seconds.

Trigger output from TIME LAPSE VCR

6-1

Image 34
Contents Digitalmultiplexer Graphic Symbol Explanation Digital MultiplexerIii Contents Appendix B Checking Points in Trouble Introduction IntroductionName of parts and Function Move → With RS-485 cable, Remote Control can be done Indicates terminal for connecting to VCR Input/OutputWith RS-232C cable, Remote Control can be done Connects to Power CordPreparing for the Installation Physical & EnvironmentalPrecautions when Installing Page Unpacking Connecting to S-VHS VCR and S-VHS Monitor Connecting to Other DevicesConnecting to normal VCR and Monitor OUT terminal on the VCRConnecting to Time Lapse VCR Connecting to Alarm Sensor CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 Remote Control by connecting to PCAscii Ascii AautoMON button → Address + 1 input → Enter Remote Control using SSC-1000RS-485Monitor OUT Control Spot OUT ControlBasic Method to use When desiring to see in the live screen/replay screenWhen desiring to see in the Triplex screen Initial operationWhen desiring to see in the Full screen When desiring to see in the division screenWhen desiring to see automatic sequential conversion screen When desiring to see in the zoom screen When desiring to see the stop screenFull Mode When desiring to see in the record screen When desiring to see in the PIP screenWhen desiring to see output of VCR as it is REC OUT SET Type TLV Setting of Program MenuRecord setting of each camera Duty SET Reservation OFFREC Reservation Start Time REC Duty SET CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9END Time ALL Setting of display modeSequence Loss Detect Loss Info Alarm Info Motion Info PB Display ALL Spot OUT Cvbs PIP SizeAlarm S/W Time SequenceBlinking character moves if pressing →, → button Setting of title by channelYou can set of each channel Enter button at a position desired to set titleIjklmnopqrstuvwxyz Title SETDATE/TIME SET Display Type Setting of alarm Setting of motionXxxxxxxxxxx Password Check OFF Alarm Buzzer Loss Buzzer Summer Time System settingPassword Change Baud RateEnter the current password in order Password Change Password Check NEW Password ConfirmIs displayed on screen when entering password Time Lapse record mode Normal record modeRecording Reservation record Weight value REC Duty recordAlarm weight value record REC DutyAlarm record Alarm occurrence conditionsAlarm release Alarm signal standardOperation in video loss Alarm/Loss list referenceOperation in motion detection Appendix a Specifications Outside Drawing Ensure power cord is properly inserted Appendix B Checking points in trouble