Samsung AR10NVFSCURNSV manual Installing and connecting the drain hose, Install the drain hose

Page 32

Installation

WARNING

In case of extending the electric wire, please DO NOT use a round-shaped

pressing socket.

Incomplete wire connections can cause electric shock or a fire.

Step 2.3 Installing and connecting the drain hose

1Install the drain hose.

Drain hose

Assembly pipe

Connection hose

Wall

 

 

Indoor unit

 

 

Drain hose

 

Water

 

 

Slant downwards

Slant upwards

Dipped in water

 

 

5 cm

 

 

less

Bent

Too small

Ditch

Too small

 

clearance

clearance

2Pour water into the drain pan. Check whether the hose is well drained.

CAUTION

Make sure that the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Inadequate installation may cause water leakage.

If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

Do not box in or cover the drain hose connection.

Drain hose connection must be easily accessible and serviceable.

Step 2.4 Optional: Extending the drain hose

Drain hose (A) Extension drain hose (B)

(A)(B)

Drain hose

Extension drain hose

20 mm or more Foam insulation

Vinyl tape

32English

Image 32
Contents Air conditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourselfDo not operate the appliance with wet hands Timer indicator Operation indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesOperation modes Remote Control OperationControlling temperature Horizontal air flow manual Controlling fan speedControlling air flow direction Step cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationFan mode Quick Smart FeaturesAuto mode Fast function Comfort functionQuiet function Beep sound functionCool mode When the Single user function starts, Button Cool mode Select Single userEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Problem Solution Timed on/off Function does not work Setting the time Indicator blinksCheck whether the drains are clean. Clean them regularly An error is indicatedInstallation of the unit General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyCases Choosing the installation locationMinimum clearances for the outdoor unit Checking and preparing accessories and tools AccessoriesUnpacking Unpacking the indoor unitTools Optional accessoriesAccessories in the outdoor unit package Taping the pipes, cables, and drain hose Drilling a hole through the wallIndoor Unit Installation Apply heat to the contraction tube to contract it Optional Extending the power cablePrepare the following tools Optional Extending the drain hose Installing and connecting the drain hoseInstall the drain hose Optional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one sideOutdoor Unit Installation PipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant RefrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Off, Blinking, On LEDPumping down for removing the product Press the Power button to stop the trial operationPerforming final check and trial operation English English Questions or COMMENTS?