Samsung AR10NVFSCURNSV Safety Information, Failing to do so may result in electric shock or fire

Page 4

Safety Information

Safety Information

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact centre or find help and information online at www.samsung.com.

WARNING

Hazards or unsafe practices that may result in severe personal injury or death.

CAUTION

Hazards or unsafe practices that may result in minor personal injury or property damage.

Follow directions.

Do NOT attempt.

Make sure the machine is grounded to prevent electric shock.

Cut off the power supply.

Do NOT disassemble.

FOR INSTALLATION

WARNING

Use a power cord with this product's power specifications or higher and use the power cord for this appliance only. In addition, do not use an extension cord.

Extending the power cord may result in electric shock or fire.

Do not use an electric transformer. This may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury and may also void warranty on the installed product.

Install an Isolation Switch next to the Air Conditioner (but not on the panels of the Air Conditioner) and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock, fire, explosion, or problems with the product.

Do not install this appliance near a heater, or inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (or rain). Do not install this appliance in a location where gas may leak.

This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failing to do so may result in electric shock, fire, and explosion.

Make sure to use a socket-outlet with ground.

4English

Image 4
Contents Air conditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not clean the inside of the air conditioner by yourselfDo not drink the water from the air conditioner Timer indicator Operation indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort functionQuiet function Beep sound functionCool mode When the Single user function starts, Button Cool mode Select Single userEnergy-Saving Operation Single user functionTimed on/Timed off function Good’sleep function Cleaning at a Glance Running Auto cleanCleaning duration Minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Problem Solution Timed on/off Function does not work Setting the time Indicator blinksCheck whether the drains are clean. Clean them regularly An error is indicatedInstallation of the unit General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyMinimum clearances for the outdoor unit Choosing the installation locationCases Checking and preparing accessories and tools AccessoriesUnpacking Unpacking the indoor unitAccessories in the outdoor unit package Optional accessoriesTools Taping the pipes, cables, and drain hose Drilling a hole through the wallIndoor Unit Installation Prepare the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Optional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one sideOutdoor Unit Installation PipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant RefrigerantRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Off, Blinking, On LEDPerforming final check and trial operation Press the Power button to stop the trial operationPumping down for removing the product English English Questions or COMMENTS?