Samsung AR10NVFSCURNSV manual Fixing the installation plate, When fixing the indoor unit on a wall

Page 35

CAUTION

If you need a pipe longer than specified in piping codes and standards, you must add refrigerant to the pipe. Otherwise, the indoor unit may freeze.

While removing burrs, put the pipe face down to make sure that the burrs do not get in to the pipe.

Step 2.8 Fixing the installation plate

You can install the indoor unit on a wall, window frame, or gypsum board.

WARNING

Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit. If you install the indoor unit in a place where it is not strong enough to withstand the unit's weight, the unit could fall and cause injury.

Liquid service port

 

 

Gas service port

<High pressure>

 

 

<Low pressure>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When fixing the indoor unit on a wall

Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic anchor

20 mm

Wall

 

 

 

Correct

 

Inclined

Cracked

Uneven

Damaged

 

 

thickness

surface

<Flare nut>

NOTE

Excessive torque may cause gas leakage. When extending the pipe with welding or brazing, ensure that nitrogen is used during the welding or brazing process. The joint must be accessible and serviceable.

CAUTION

Tighten the flare nut at the specified torque. If the flare nut is over-tightened, it may break to cause leakage of refrigerant gas.

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

 

 

 

 

 

 

**09*******

30

96

38

 

30

**12*******

 

 

 

 

 

 

**18*******

38

126

70

 

38

**24*******

 

 

 

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

NOTE

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

When fixing the indoor unit on a window frame

1Determine the positions of the wooden uprights to be attached to the window frame.

2Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

3Attach the installation plate to the wooden upright using tapping screws.

Installation

English 35

Image 35
Contents Air conditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply This may result in children seriously injuring themselves Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in electric shock or burnsDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourselfDo not operate the appliance with wet hands Display Timer indicatorOperation indicator Indoor Unit OverviewInserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Horizontal air flow manual Controlling fan speedControlling air flow direction Step cooling function Cool modeCooling Operation Dehumidifying Operation Dry modeFan mode Quick Smart FeaturesAuto mode Comfort function Fast functionBeep sound function Quiet functionSingle user function Cool mode When the Single user function starts,Button Cool mode Select Single user Energy-Saving OperationTimed on/Timed off function Good’sleep function Do not clean the display by using alkaline detergent Cleaning at a GlanceRunning Auto clean Cleaning duration MinutesCleaning the filter Troubleshooting An error is indicated Problem Solution Timed on/offFunction does not work Setting the time Indicator blinks Check whether the drains are clean. Clean them regularlyGeneral information Installation of the unitInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerCases Choosing the installation locationMinimum clearances for the outdoor unit Unpacking the indoor unit Checking and preparing accessories and toolsAccessories UnpackingTools Optional accessoriesAccessories in the outdoor unit package Drilling a hole through the wall Taping the pipes, cables, and drain hoseIndoor Unit Installation Apply heat to the contraction tube to contract it Optional Extending the power cablePrepare the following tools Optional Extending the drain hose Installing and connecting the drain hoseInstall the drain hose Optional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a window frame Fixing the installation plateWhen fixing the indoor unit on a wall Fix the installation plate without inclining to one side When fixing the indoor unit on a gypsum boardOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationPipes Fixing the outdoor unit in placeEvacuating the air Refrigerant Adding refrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode LED Off, Blinking, OnPumping down for removing the product Press the Power button to stop the trial operationPerforming final check and trial operation English English Questions or COMMENTS?