Desa RC70ET, BC55CT, BC115DT, BC165DT, UKC115DT, UKC70ET, UKC55CT Ignitor, Replace combustion chamber

Page 12

SERVICE PROCEDURES

Continued

IGNITOR

1.Remove upper shell and fan guard (See Upper Shell Removal, page 10).

2.Remove fan (see page 10).

3.Remove 4 side cover screws with a 5/16" nut driver. Remove side cover (see Figures 19 or 20, page 11).

4.Disconnect ignitor wires from ignition control assembly (see Figure 21). Pull the ignitor wires up through the hole in the lower shell.

5.Disconnect fuel line hose and air line hose. Remove photocell from photocell bracket (see Figure 21).

6.Remove combustion chamber. Stand com- bustion chamber on end with nozzle adapter bracket on top (see Figure 22).

7.Remove ignitor screw with a 1/4" nut driver. Carefully remove ignitor from nozzle adapter bracket.

CAUTION: Do not bend or strike ignitor element. Handle with care.

8.Carefully remove replacement ignitor from packing.

9.Carefully guide ignitor into opening in nozzle adapter bracket. Do not strike ignitor element. Attach ignitor to nozzle adapter bracket with screw using a 1/4" nut driver (see Figure 23). Torque .90 to 1.69 N-m (8 to 15 in-lbs) Do not over torque.

10.Replace combustion chamber.

11.Route the ignitor wires back down through the hole in the lower shell. Connect wires to the ignition control assembly (see Figure 22).

12.Replace side cover (see Figures 19 or 20, page 11).

13.Connect and route fuel line hose and air line hose to nozzle adapter assembly. See Fuel and Air Line Replacement and Proper Routing, page 14.

14.Replace photocell in photocell bracket. Route wires as shown in either (see Figure 23 or Figure 24, page 13).

15.Replace fan (see page 10).

16.Replace fan guard and upper shell (see page 10).

Combustion

Nozzle

Adapter

Chamber

Bracket

 

Air Line

Ignitor

Hose

 

Fuel

 

Line

Ignitor

Hose

Wire

 

Photocell

 

Bracket

Ignition

 

Photocell

Control

Assembly

Assembly

 

Side Cover

 

Figure 21 - Disconnecting Ignitor Wires

from Ignition Control Assembly

Ignitor Screw/

 

Washer Assembly

 

 

Ignitor

Ignitor

Nozzle

Element

Photocell

Adapter

Bracket

Bracket

Combustion

Nozzle Adapter

Chamber

Bracket Opening

 

Figure 22 - Ignitor Replacement

Combustion

 

Chamber

 

Nozzle

 

Adapter

 

Bracket

Nozzle/

 

Photocell

Adapter

Assembly

Bracket

 

Air Line

Fuel Line Hose

Hose

 

Figure 23 - Removing Air and Fuel Line

Hoses (40/55/70 Models Only)

12

www.desatech.com

116170-01A

Image 12
Contents Table of Contents Safety Information Unpacking Product IdentificationFuels VentilationTheory of Operation Assembly For 40, 55 and 70 Models onlyFor 115 and 165 Models only Tools NeededOperation To Start HeaterTo Stop Heater To Restart HeaterSTORING, Transporting or Shipping Replace drain plug if providedPreventative Maintenance Schedule TroubleshootingFault Condition Possible Cause Remedy Control assembly Defective ignitor Assembly SemblyDirty fuel filter Ment, Obstruction in nozzleService Procedures Upper Shell RemovalFAN AIR OUTPUT, AIR Intake and LintPump Pressure Adjustment Fuel FilterReplace filter end cover Ignitor Replace combustion chamberNozzle Assembly Replace fan see Fan,Place plastic hex-body into vise and lightly tighten Fuel and AIR Line Replacement and Proper Routing Pump Rotor Procedure if Rotor is BindingSpecifications Model Size 115 165Illustrated Parts Breakdown Models BC40 and RC40Parts List NTC-4CModels BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET and UKC70ET See 39 13 Wire Not Shown Connects T-stat to Ignition Control Assembly Burner Head Assembly FHPF3-6CFHPF3-5C Wheels and Handle Parts List NTC-3BZWiring Diagrams Wiring DiagramsAccessories Ignition Control Assembly Photocell Tester HA1170Thermostat KIT HA1210 AIR Gauge KIT HA1180116170-01A Warranty and Repair Service Keep this WarrantyTable DES Matières Remplir pour vos dossiersLA Sécurité Alimentation en carburantDéballage Identification DU ProduitCarburants Théorie DE FonctionnementLa production dune odeur particulière Cas dextinction de la flammeAssemblage Pour LES Modèles 40, 55 ET 70 UniquementPour LES Modèles 115 ET Outils nécessairesFonctionnement Pour Allumer Lappareil DE ChauffagePour Arrêter Lappareil DE Chauffage Pour Rallumer Lappareil DE ChauffageEntreposage Transport OU Expédition Réinitialisation de lappareil de chauffageRemettez le bouchon de vidange en place si nécessaire État DE LA Panne Cause Possible Solution Calendrier Dentretien PréventifDépannage Photoélectrique mal installé Pas de carburant dans leRéservoir Du kérosène Sallume pas Mauvaise pression PompeRetrait DE LA Partie Supérieure DE Lhabillage VentilateurFiltres DE Sortie DAIR, DE Prise Dair ET DE PeluchesAjustement DE LA Pression DE LA Pompe Filtre À CarburantRemplacez le couvercle des filtres Important ne huilez pas les filtres. Filtre de prise dairAllumeur Assemblage DE LA Buse DaérationRotor DE Pompe Procédure si le rotor se bloque Tuyau de la conduite dair etAssemblage DE Commande DE Lallumeur Taille du modèle 115 165VUE Détaillée DES Pièces Modèles BC40 ET RC40Liste DES Pièces Modèles BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET ET UKC70ET Voir Modèles De la commande dallumage ou au thermostat si présent Assemblage DE Tête DE Brûleur Vis102001-30 Moteur 079975-02 Corps de pompe Liste DE Pièces DES Roues ET DE LA Poignée Diagrammes DE Câblage De la commande ’allumeurAccessoires PRÊT-À-MONTER DE LA Jauge Dair HA1180PRÊT-À-MONTER DE Roues ET DE Poignée Renforcées HA1202 Prêt À Monter Pour Thermostat HA1210116170-01A Service DE Garantie ET DE Réparation Conservez Cette Garantie