OPERATION
IMPORTANT: Review and under- stand the warnings in the Safety Information section, page 2. They are needed to safely oper- ate this heater. Follow all local ordinances and codes when using this heater.
TO START HEATER
1.Follow all ventilation and safety information.
2.Locate heater to provide maximum circulation of the heated air. Follow all location require- ments noted in Safety Information, page 2.
3.Fill fuel tank with kerosene, #1#2 diesel/fuel oil, JET A or
4.Attach fuel cap.
5.For thermostat models, turn thermostat knob clockwise to the high position.
6.Plug heaterʼs power cord into approved, grounded,
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord
11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord
7.Plug extension cord into standard 120 volt/60 hertz,
Note: For heater with ON/OFF switch, push switch to ON() position and heater should start in 5 seconds. If heater does not start, see Troubleshooting, page 9.
8.For thermostat models, adjust thermostat knob to the desired setting. Note: A cold heater may affect the thermostat setting. This thermostat is a
TO STOP HEATER
Without ON/OFF Switch
Unplug extension cord from outlet.
With ON/OFF Switch
Push ON/OFF switch to OFF (O) position. Unplug heater when not in use.
TO RESTART HEATER
Without ON/OFF Switch
1.Unplug extension cord from outlet and wait 10 seconds. (Wait two minutes if heater has been running.)
2.Repeat steps under To Start Heater.
With ON/OFF Switch
1.Push ON/OFF switch to OFF (O) position and wait 10 seconds (2 minutes if heater has been running).
2.Repeat steps under To Start Heater.
ON/OFF
Switch with
Light
Figure 8 - ON/OFF Switch, 55/70 Models
ON/OFF
Switch with
Light
Figure 9 - ON/OFF Switch, 115/165
Models
6 | www.desatech.com |