Desa BC165DT, BC55CT, BC115DT, UKC115DT, UKC70ET, UKC55CT, UKC165DT Specifications, Model Size 115 165

Page 15

SERVICE PROCEDURES

Continued

Note: If rotor is still binding, proceed as follows.

13.Perform steps 1 through 6.

14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “figure 8” motion four times (see Figure 31).

15.Reinstall insert and rotor.

16.Perform steps 10 through 12.

Gap Adjusting Screw

Blade

.003"/.004"

(.076-.101 mm)

Gap Measured

With Feeler

Gauge

Rotor

IGNITION CONTROL ASSEMBLY WARNING: High voltage!

1.Unplug heater.

2.Remove side cover screws (4) using 5/16" nut- driver to expose ignition control assembly.

3.Remove fuse cover (see Figure 32).

4.Remove fuse from fuse clips (see Figure 32).

5.Replace fuse with fuse of the same type and rating (GMA-10). Do not substitute a fuse with a higher current rating.

6.Replace fuse cover (see Figure 32).

7.Replace side cover (see Figures 19 or 20, page 11).

Fuse Clips

Fuse

Cover

 

 

Fuse

Gap Adjusting Screw

Figure 30 - Gap Adjusting Screw

Locations

Sandpaper

Figure 32 - Replacing Fuse

Figure 31 - Sanding Rotor

 

SPECIFICATIONS

 

Model Size

40

55

70

115

165

Output Rating (Btu/Hr)

40,000

55,000

70,000

115,000

165,000

Fuel

Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*

Fuel Tank Capacity

 

 

 

 

 

(U.S. Gal./Liters)

3/11.3

5/18.9

5/18.9

9/34

13.5/51

Fuel Consumption

 

 

 

 

 

(Gal. Per Hr/Liters Per Hr)

.3/1.14

.44/1.67

.52/1.97

.85/3.00

1.2/4.54

Pump Pressure (psi)

3.0

3.4

4.7

5.1

5.6

Electric Requirements

120 V/60 HZ (Same All Models)

 

 

Amperage (Normal Run)

2.0

2.0

2.8

3.6

3.6

Motor RPM

1725

1725

3440

3440

3440

Hot Air Output (CFM)

170

180

360

490

575

Shipping Weight

32/14.5

35/15.9

35/15.9

54/24.5

65/29.5

(Approximate lbs./kg)

 

 

 

 

 

Heater Weight without Fuel

28/12.2

30/14

30/14

46/21

55/25

(Approximate lbs./kg)

 

 

 

 

 

*Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter main- tenance. Use in extreme cold temperatures may require nontoxic anti-icer additives.

116170-01A

www.desatech.com

15

Image 15
Contents Table of Contents Safety Information Product Identification UnpackingFuels VentilationTheory of Operation Tools Needed AssemblyFor 40, 55 and 70 Models only For 115 and 165 Models onlyTo Restart Heater OperationTo Start Heater To Stop HeaterReplace drain plug if provided STORING, Transporting or ShippingPreventative Maintenance Schedule TroubleshootingFault Condition Possible Cause Remedy Obstruction in nozzle Control assembly Defective ignitorAssembly Sembly Dirty fuel filter Ment,AIR OUTPUT, AIR Intake and Lint Service ProceduresUpper Shell Removal FANPump Pressure Adjustment Fuel FilterReplace filter end cover Replace combustion chamber IgnitorNozzle Assembly Replace fan see Fan,Place plastic hex-body into vise and lightly tighten Pump Rotor Procedure if Rotor is Binding Fuel and AIR Line Replacement and Proper RoutingModel Size 115 165 SpecificationsModels BC40 and RC40 Illustrated Parts BreakdownNTC-4C Parts ListModels BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET and UKC70ET See 39 13 Wire Not Shown Connects T-stat to Ignition Control Assembly FHPF3-6C Burner Head AssemblyFHPF3-5C NTC-3BZ Wheels and Handle Parts ListWiring Diagrams Wiring DiagramsAIR Gauge KIT HA1180 AccessoriesIgnition Control Assembly Photocell Tester HA1170 Thermostat KIT HA1210116170-01A Keep this Warranty Warranty and Repair ServiceRemplir pour vos dossiers Table DES MatièresAlimentation en carburant LA SécuritéIdentification DU Produit DéballageCas dextinction de la flamme CarburantsThéorie DE Fonctionnement La production dune odeur particulièreOutils nécessaires AssemblagePour LES Modèles 40, 55 ET 70 Uniquement Pour LES Modèles 115 ETPour Rallumer Lappareil DE Chauffage FonctionnementPour Allumer Lappareil DE Chauffage Pour Arrêter Lappareil DE ChauffageEntreposage Transport OU Expédition Réinitialisation de lappareil de chauffageRemettez le bouchon de vidange en place si nécessaire État DE LA Panne Cause Possible Solution Calendrier Dentretien PréventifDépannage Pompe Photoélectrique mal installéPas de carburant dans le Réservoir Du kérosène Sallume pas Mauvaise pressionPrise Dair ET DE Peluches Retrait DE LA Partie Supérieure DE LhabillageVentilateur Filtres DE Sortie DAIR, DEImportant ne huilez pas les filtres. Filtre de prise dair Ajustement DE LA Pression DE LA PompeFiltre À Carburant Remplacez le couvercle des filtresAllumeur Daération Assemblage DE LA BuseTuyau de la conduite dair et Rotor DE Pompe Procédure si le rotor se bloqueTaille du modèle 115 165 Assemblage DE Commande DE LallumeurModèles BC40 ET RC40 VUE Détaillée DES PiècesListe DES Pièces Modèles BC55CT, RC55CT, UKC55CT, BC70ET, RC70ET ET UKC70ET Voir Modèles De la commande dallumage ou au thermostat si présent Vis Assemblage DE Tête DE Brûleur102001-30 Moteur 079975-02 Corps de pompe Liste DE Pièces DES Roues ET DE LA Poignée De la commande ’allumeur Diagrammes DE CâblagePrêt À Monter Pour Thermostat HA1210 AccessoiresPRÊT-À-MONTER DE LA Jauge Dair HA1180 PRÊT-À-MONTER DE Roues ET DE Poignée Renforcées HA1202116170-01A Conservez Cette Garantie Service DE Garantie ET DE Réparation