INSTALLATION
Installing Damper Clamp Accessory For Vented Operation Installing Heater Base Assembly
11
INSTALLATION
Continued
INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION
(Remote-Ready Models Only)
Note: When used as a vented heater, appliance must be installed only in a
If your heater is a
1.The fireplace does not meet the clearance to combustibles re- quirements for
2.State or local codes do not permit
3.You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 34). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.
INSTALLING HEATER BASE ASSEMBLY
WARNING: You must secure this heater to fire- place floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
WARNING: If installing in a sunken fireplace, spe- cial care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and con- trols being damaged. Raise fireplace floor with noncom- bustible material. Make sure material is secure.
CAUTION: Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by sides of base.
IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning of Thermostat Sensing Bulb, page 27.
Area of Various Standard
Round Flues
Diameter (ins.) | Area (sq. ins.) |
|
|
5" | 20 sq. inches |
6" | 29 sq. inches |
7" | 39 sq. inches |
8" | 51 sq. inches |
|
|
Chimney | Minimum Permanent |
Height (ft.) Flue Opening (sq. ins.) | |
6' to 15' | 39 sq. inches |
15' to 30' | 29 sq. inches |
Damper |
|
Clamp |
|
| Damper Clamp |
Damper | Damper |
Damper
Masonry Fireplace | Manufactured Fireplace |
Figure 10 - Attaching Damper Clamp
Installation Items Needed
•hardware package (provided with heater)
•approved flexible gas hose and fitting (not provided) (if allowed by local codes)
•sealant (resistant to propane/LP gas, not provided)
•electric drill with 3/16" drill bit (metal or masonry as applicable)
•flathead screwdriver
1.Connect fitting to base as shown in Figure 11. Connect approved flexible gas hose to fitting in base (see Figure 11). IMPORTANT: Hold gas fitting with wrench when connecting flexible gas hose.
Flexible Gas Hose (if |
|
allowed by local codes) | Fitting |
Figure 11 - Attaching Flexible Gas Hose to Heater