Desa CSG3930NR Installing Damper Clamp Accessory for Vented Operation, Remote-Ready Models Only

Page 11

INSTALLATION

Installing Damper Clamp Accessory For Vented Operation Installing Heater Base Assembly

11

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

(Remote-Ready Models Only)

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually-controlled, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles re- quirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 34). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

INSTALLING HEATER BASE ASSEMBLY

WARNING: You must secure this heater to fire- place floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, spe- cial care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and con- trols being damaged. Raise fireplace floor with noncom- bustible material. Make sure material is secure.

CAUTION: Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by sides of base.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning of Thermostat Sensing Bulb, page 27.

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

Chimney

Minimum Permanent

Height (ft.) Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Damper

 

Clamp

 

 

Damper Clamp

Damper

Damper

Damper

Masonry Fireplace

Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose and fitting (not provided) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

electric drill with 3/16" drill bit (metal or masonry as applicable)

flathead screwdriver

1.Connect fitting to base as shown in Figure 11. Connect approved flexible gas hose to fitting in base (see Figure 11). IMPORTANT: Hold gas fitting with wrench when connecting flexible gas hose.

Flexible Gas Hose (if

 

allowed by local codes)

Fitting

Figure 11 - Attaching Flexible Gas Hose to Heater

For morevisit www..com

110021-01G

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation See Between 8 Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesRemote-Ready Models Only Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor 30 Model Shown Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Log #4 Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Lighting Instructions Attaching Grate to Base AssemblyOperating Heater Adding Lava RockShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationREMOTE-READY Models For Your Safety Read Before Lighting Control Knobs and Ignitor Button Locations Shown Optional HAND-HELD Remote OperationON/OFF Series Models Ghrcb and Cghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbREMOTE-READY Models only SpecificationsWiring Diagram Illustrated Parts Breakdown Illustrated Parts Breakdown THERMOSTAT-CONTROLLED Models Parts List2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Parts Under Warranty Replacement PartsService Hints Technical ServiceNot a UPC