Desa CSG3930PR, CSG3930NR installation manual Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

PRODUCT IDENTIFICATION

4

OPTIONAL REMOTE CONTROL ACCESSORIES

4

LOCAL CODES

4

UNPACKING

4

PRODUCT FEATURES

5

AIR FOR COMBUSTION AND VENTILATION

5

INSTALLATION

8

OPERATING HEATER

17

INSPECTING BURNERS

22

CLEANING AND MAINTENANCE

23

TROUBLESHOOTING

24

OPTIONAL POSITIONING OF THERMOSTAT

 

SENSING BULB

27

SPECIFICATIONS

28

WIRING DIAGRAM

28

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

29

ACCESSORIES

34

OWNER’S REGISTRATION FORM

35

REPLACEMENT PARTS

37

SERVICE HINTS

37

TECHNICAL SERVICE

37

SAFETY INFORMATION

WARNINGS

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause property damage and serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its con- trols can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

WARNING: This appliance is for installation only in a solid-fuel burning fireplace or approved ventless firebox enclosure.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when run- ning heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the room with heater. When using the hand-held remote accessory (Remote-Ready Models Only), keep selector switch in the OFF position to prevent chil- dren from turning on burners with remote.

For..com

110021-01G

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Local Codes Optional Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation Minimum Noncombustible Material Clearances See Between 8Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Remote-Ready Models OnlyConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor 30 Model ShownExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Logs Installing Log #4 Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Adding Lava Rock Attaching Grate to Base AssemblyOperating Heater Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Control Knobs and Ignitor Button Locations ShownSafety Features Manual ModeAuto Thermostatic Mode ON/OFF Series Models Ghrcb and CghrcbBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillaryREMOTE-READY Models only SpecificationsWiring Diagram Illustrated Parts Breakdown Illustrated Parts Breakdown Parts List THERMOSTAT-CONTROLLED Models2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Technical Service Replacement PartsService Hints Parts Under WarrantyNot a UPC