OPERATING HEATER (REMOTE-READY MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Optional Remote Operation

OPERATING HEATER

Continued

11.To light the front/rear burners, push in and turn rear burner

control knob counterclockwise to the ON position.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.

Control Knob

 

 

 

 

Rear Burner

 

 

 

 

Control Knob

 

ILOT

O

 

 

 

P

 

 

 

F

N

 

 

 

F

 

 

 

AUTO OFF ON

O

 

 

 

 

 

 

 

Selector

 

Ignitor Button

 

Switch

 

 

 

 

Figure 31 - Control Knobs and Ignitor Button Locations (Shown

as Supplied, No Remote Control Operation)

 

Pilot Burner

Ignitor

Ignitor Electrode

 

 

Thermocouple

Thermocouple

Electrode

 

Pilot Burner

 

 

 

 

 

 

 

 

Figure 32 - Pilot (Propane/LP) Figure 33 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise to the OFF position.

2. Turn rear burner control knob clockwise to the OFF position.

3a. Set selector switch in the OFF position.

3b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Turn rear burner control knob clockwise to the OFF position.

3.Use remote control manual OFF button.

4.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 20.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, page 19 and column 1.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, pages 38 and 39). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 19.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 34). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

Control Knob

Rear Burner

 

Control Knob

 

 

ILOT

O

 

 

P

 

 

FF

N

AUTO

OFF

O

 

ON

 

Selector

Switch

Ignitor Button

Figure 34 - Control Knobs, Selector Switch and Ignitor Button Locations for Hand-Held Remote Operation

For..com

110021-01G

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation Minimum Noncombustible Material Clearances See Between 8Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor 30 Model ShownExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Logs Installing Log #4 Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Attaching Grate to Base Assembly Operating HeaterAdding Lava Rock Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Control Knobs and Ignitor Button Locations ShownManual Mode Auto Thermostatic ModeSafety Features ON/OFF Series Models Ghrcb and CghrcbBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillaryREMOTE-READY Models only SpecificationsWiring Diagram Illustrated Parts Breakdown Illustrated Parts Breakdown Parts List THERMOSTAT-CONTROLLED Models2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Replacement Parts Service HintsTechnical Service Parts Under WarrantyNot a UPC