CLEANING AND MAINTENANCE

Cleaning Burner Injector Holders and Pilot Air Inlet Holes Logs

23

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passageways of heater clean. In- spect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to exces- sive lint from carpeting, pet hair, bedding material, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in soot- ing and property damage.

CLEANING BURNER INJECTOR HOLDERS AND PILOT AIR INLET HOLES

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tubes and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burners, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figures 41 or 42).

3.Blow air through the ports/slots and holes in the burners.

4.Check the injector holders located at the end of the burner tubes again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holders.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 43). With the unit off, lightly blow air through the air inlet hole. The access hole for propane/LP pilot is on the front of the burner carriange as shown in Figure 43. The

access hole for natural pilot is behind the pilot bracket on the top of burner carriage (see Figure 43). You may blow through a drinking straw if compressed air is not available.

Burner

Injector Holder

Tube

 

Primary Air

Inlet Holes

Figure 41 - Injector Holder On Outlet Burner Tube - Rear Burner

 

Ports/Slots

 

 

Injector

Injector

 

Holder

 

Holder

 

 

Access Hole

Primary Air

 

Inlet Holes

 

in Base

 

 

 

 

Control

 

 

Knob

 

 

Primary Air Inlet Holes

YELLOW FLAME

BLUE FLAME

(CTB Models)

(VRL and CSG Models)

Figure 42 - Injector Holder On Outlet Burner Tubes -

Front and Middle Burners

 

Pilot Bracket

Access Hole

 

Pilot Assembly

for Cleaning

Natural Pilot

Access Hole

 

for Cleaning

 

Propane/LP

Pilot Air

Pilot

Inlet Hole

 

Figure 43 - Cleaning Pilot Air Inlet Hole (Your pilot may vary from pilots shown)

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 15 and 16, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

For morevisit www..com

110021-01G

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation and Clearances for VENT-FREE Operation See Between 8 Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesRemote-Ready Models Only Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor 30 Model Shown Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing Log #4 Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Lighting Instructions Attaching Grate to Base AssemblyOperating Heater Adding Lava RockShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationREMOTE-READY Models For Your Safety Read Before Lighting Control Knobs and Ignitor Button Locations Shown Optional HAND-HELD Remote OperationON/OFF Series Models Ghrcb and Cghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesBurner Flame Patterns Inspecting BurnersPilot Flame Pattern Logs Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbREMOTE-READY Models only SpecificationsWiring Diagram Illustrated Parts Breakdown Illustrated Parts Breakdown THERMOSTAT-CONTROLLED Models Parts List2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Parts Under Warranty Replacement PartsService Hints Technical ServiceNot a UPC