INSTALLATION
Connecting To Gas Supply (Cont.)
13
INSTALLATION
Continued
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14 or 15, depending on your model).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 14 or 15, depending on your model. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings
CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings
External Regulator
Propane/LP
Supply Tank
Vent Pointing Down
Figure 13 - External Regulator With Vent Pointing Down
| CSA | |
PROPANE/LP - | Shutoff Valve With 1/8" NPT Tap* | |
From External |
| |
Regulator |
| |
(11" W.C.** | Approved Flexible | |
to 14" W.C. | ||
Gas Hose (if allowed | ||
Pressure) | ||
by local codes) | ||
| ||
NATURAL - |
| |
From Gas | 3" Minimum | |
Meter | ||
(5" W.C.** |
| |
to 10.5" W.C. |
| |
Pressure) | Gas Regulator | |
|
Tee Cap Pipe
Joint Nipple
Sediment Trap
Figure 14 - Gas Connection (Thermostat-Controlled Models Only)
|
| CSA |
PROPANE/LP - |
| Shutoff Valve With 1/8" NPT Tap* |
|
| |
From External |
|
|
Regulator |
| Approved Flexible |
(11" W.C.** |
| Gas Hose (if allowed |
to 14" W.C. |
| by local codes) |
Pressure) |
|
|
NATURAL - |
|
|
From Gas |
|
|
Meter |
|
|
(5" W.C.** | 3" Minimum | |
to 10.5" W.C. | ||
Pressure) |
|
|
Tee | Pipe |
|
Joint | Nipple Cap | Gas Control |
|
| Valve |
Sediment Trap |
|
Figure 15 - Gas Connection (Remote-Ready Models Only)
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment.
For morevisit www..com