Desa CSG3930NR, CSG3930PR installation manual External Regulator With Vent Pointing Down

Page 13

INSTALLATION

Connecting To Gas Supply (Cont.)

13

INSTALLATION

Continued

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14 or 15, depending on your model).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 14 or 15, depending on your model. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings (Thermostat-Controlled Mod- els Only).

CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings (Remote-Ready Models Only).

External Regulator

Propane/LP

Supply Tank

Vent Pointing Down

Figure 13 - External Regulator With Vent Pointing Down

 

CSA Design-Certified Equipment

PROPANE/LP -

Shutoff Valve With 1/8" NPT Tap*

From External

 

Regulator

 

(11" W.C.**

Approved Flexible

to 14" W.C.

Gas Hose (if allowed

Pressure)

by local codes)

 

NATURAL -

 

From Gas

3" Minimum

Meter

(5" W.C.**

 

to 10.5" W.C.

 

Pressure)

Gas Regulator

 

Tee Cap Pipe

Joint Nipple

Sediment Trap

Figure 14 - Gas Connection (Thermostat-Controlled Models Only)

 

 

CSA Design-Certified Equipment

PROPANE/LP -

 

Shutoff Valve With 1/8" NPT Tap*

 

 

From External

 

 

Regulator

 

Approved Flexible

(11" W.C.**

 

Gas Hose (if allowed

to 14" W.C.

 

by local codes)

Pressure)

 

 

NATURAL -

 

 

From Gas

 

 

Meter

 

 

(5" W.C.**

3" Minimum

to 10.5" W.C.

Pressure)

 

 

Tee

Pipe

 

Joint

Nipple Cap

Gas Control

 

 

Valve

Sediment Trap

 

Figure 15 - Gas Connection (Remote-Ready Models Only)

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 34.

**Minimum inlet pressure for purpose of input adjustment.

For morevisit www..com

110021-01G

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type See Between 8 Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Remote-Ready Models OnlyAttaching Base Assembly to Fireplace Floor 30 Model Shown Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Log #4 Model CSG3924NR Shown Installing LogsInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Operating Heater Attaching Grate to Base AssemblyAdding Lava Rock Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Control Knobs and Ignitor Button Locations Shown Optional HAND-HELD Remote OperationAuto Thermostatic Mode Manual ModeSafety Features ON/OFF Series Models Ghrcb and CghrcbPilot Flame Pattern Inspecting BurnersBurner Flame Patterns Cleaning Burner Injector Holders and Pilot AIR Inlet Holes Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbWiring Diagram SpecificationsREMOTE-READY Models only Illustrated Parts Breakdown Illustrated Parts Breakdown THERMOSTAT-CONTROLLED Models Parts List2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Service Hints Replacement PartsTechnical Service Parts Under WarrantyNot a UPC