Desa CSG3930PR, CSG3930NR Troubleshooting, Observed Problem Possible Cause Remedy

Page 24

24

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA Heating Products’ technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot

 

tor cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

 

base panel.

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

6.

Ignitor electrode positioned wrong

6.

Replace pilot assembly

 

 

7.

Ignitor electrode broken

7.

Replace pilot assembly

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

 

PILOT position

 

position

 

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

 

removed

 

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 23) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

 

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

 

knob pressed in 30 seconds

 

 

3.

Safety interlock system has been

3.

Wait one minute for safety interlock sys-

 

 

 

triggered (Termostat-Controlled Models

 

tem to reset. Repeat ignition operation

 

 

 

only)

 

 

 

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local natural or propane/LP

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

the following:

 

Maintenance, page 23) or replace ODS/

 

 

 

A) Low gas pressure

 

pilot assembly

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

6.

Thermocouple connection loose at con-

6.

Hand tighten until snug, then tighten

 

 

 

trol valve

 

1/4 turn more

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

 

8.

Control valve damaged

8.

Replace control valve

 

For

 

.

 

.com

110021-01G

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Optional Remote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation and Clearances for VENT-FREE OperationCheck GAS Type Minimum Noncombustible Material Clearances See Between 8Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor 30 Model ShownExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Log #4 Model CSG3924NR ShownInstalling Log #2 Right and Log #3 Left Model VRL30NR Shown Attaching Grate to Base Assembly Operating HeaterAdding Lava Rock Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Control Knobs and Ignitor Button Locations ShownManual Mode Auto Thermostatic ModeSafety Features ON/OFF Series Models Ghrcb and CghrcbInspecting Burners Pilot Flame PatternBurner Flame Patterns Cleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillarySpecifications Wiring DiagramREMOTE-READY Models only Illustrated Parts Breakdown Illustrated Parts Breakdown Parts List THERMOSTAT-CONTROLLED Models2325 1026 Natural Gas Models Only REMOTE-READY Models Accessories Owners Registration Form Postage Required Replacement Parts Service HintsTechnical Service Parts Under WarrantyNot a UPC