Desa CGS2718PA Installing Damper Clamp Accessory for Vented Operation, Chimney Minimum Permanent

Page 12

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fire- place with a working flue and constructed of non- combustible material.

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 30). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are in- cluded with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

 

6' to 15'

 

39 sq. inches

15' to 30'

 

29 sq. inches

 

 

 

 

 

 

Area of Various Standard Round Flues

 

 

 

Diameter (ins.)

Area (sq. ins.)

5"

 

20 sq. inches

6"

 

29 sq. inches

7"

 

39 sq. inches

8"

 

51 sq. inches

 

 

 

Damper

 

Damper

 

Clamp

 

Damper

Damper

Masonry Fireplace

Manufactured

 

Fireplace

Figure 10 - Attaching Damper Clamp

INSTALLING HEATER BASE ASSEMBLY

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important war- ranty and safety information.

WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard against sooting and controls be- ingdamaged.Raisefireplacefloor with noncombustible material. Make sure material is secure.

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assem- bly by grates.

12

www.desatech.com

113101-01A

Image 12
Contents 24 Variable MANUALLY-CONTROLLED Models Patent PendingTable of Contents Safety Information Product Identification Product Features Local CodesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Log Size Side Wall CeilingMinimum Firebox Size Material Requirements for Distance a Safe Installation Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance when Using a Hood Mantel ClearancesDetermining Minimum Mantel Clearance Minimum Mantel Clearances When Using Hood Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyChimney Minimum Permanent Diameter ins Area sq. insConnecting to GAS Supply Installation Items NeededNatural Propane/LPChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater Gas Connections Installing Back LogInstalling Crossover Logs Operating Heater What to do if YOU Smell GASLighting Instructions Ignitor Button Control KnobManual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Ignitor Button Control Knob Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance ODS/PILOT and BurnerBurner Injector Holder and Pilot AIR Inlet Hole Technical Service Service HintsReplacement Parts Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Gas leak. See Warning Statement aboveOptional Positioning Thermostat Sensing Bulb For Masonry and FACTORY- Built Metal FireplaceStatement on Locating Thermostat Sensing Specifications AccessoriesEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Winchester OAK ModelsIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.