Desa CLD3924NTB, CLD3018PTA, SGS3124NA Connecting to GAS Supply, Installation Items Needed

Page 13

INSTALLATION

Continued

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning Of Thermostat Sensing Bulb, page 28.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

electric drill with 3/16" drill bit

flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper position on heater base (see Installing Logs, page 16).

5.Center heater base and logs front-to-front and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mount- ing brackets (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12).

Masonry

Screw

Mounting

Bracket

Figure 12 - Attaching Base Assembly to

Fireplace Floor

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP heater directly to the propane/LP supply. Propane/LP heaters require an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.

WARNING: For natural gas units, never connect heater to private (non-utility) gas wells. This gas is commonly known as

Fitting

Flexible Gas Hose

(if allowed by local codes)

Heater Gas Regulator

wellhead gas.

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

113101-01A

www.desatech.com

13

Image 13
Contents Patent Pending 24 Variable MANUALLY-CONTROLLED ModelsTable of Contents Safety Information Product Identification Local Codes Product FeaturesUnpacking AIR for Combustion VentilationUnusually Tight Construction Determining FRESH-AIR Flow for Fireplace LocationConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsLog Size Side Wall Ceiling Check GAS TypeMinimum Firebox Size Minimum Noncombustible Material Clearances Material Requirements for Distance a Safe InstallationMantel Clearances Determining Minimum Mantel Clearance when Using a HoodDetermining Minimum Mantel Clearance Floor Clearances Minimum Mantel Clearances When Using HoodInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Diameter ins Area sq. insInstallation Items Needed Connecting to GAS SupplyPropane/LP NaturalTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Back Log Pressure Testing Heater Gas ConnectionsInstalling Crossover Logs What to do if YOU Smell GAS Operating HeaterIgnitor Button Control Knob Lighting InstructionsVariable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Ignitor Button Control Knob Thermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesODS/PILOT and Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Service Hints Technical ServiceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Statement above Gas leak. See WarningFor Masonry and FACTORY- Built Metal Fireplace Optional Positioning Thermostat Sensing BulbStatement on Locating Thermostat Sensing Accessories SpecificationsEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Variable MANUALLY-CONTROLLED Winchester OAK Models Parts ListIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.