Desa CLD3018PTA, CLD3924NTB Check GAS Type, Log Size Side Wall Ceiling, Minimum Firebox Size

Page 8

INSTALLATION

Continued

NOTICE: State or local codes may only allow operation of this appliance in a vented con- figuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, thechimneyflueandfireboxmust be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue and firebox for damage. If damaged, repair flue before operating heater.

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fire- place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (Variable Manually- Controlled Models Only) (see page 12)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use only the correct gas type (natural or pro- pane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

WARNING: This appliance is equippedfor(naturalorpropane/ LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

 

Ceiling

18", 24"

 

16"

 

 

42"

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

 

 

Front

 

Rear

Size

 

Height

Depth

Width

Width*

18"

 

17"

 

14"

24"

 

20"

24"

 

17"

 

14"

28"

 

21"

*Measured at 14" Depth

8

www.desatech.com

113101-01A

Image 8
Contents 24 Variable MANUALLY-CONTROLLED Models Patent PendingTable of Contents Safety Information Product Identification Product Features Local CodesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeLog Size Side Wall Ceiling Material Requirements for Distance a Safe Installation Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Minimum Mantel Clearances When Using Hood Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyChimney Minimum Permanent Diameter ins Area sq. insConnecting to GAS Supply Installation Items NeededNatural Propane/LPTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Heater Gas Connections Installing Back LogInstalling Crossover Logs Operating Heater What to do if YOU Smell GASLighting Instructions Ignitor Button Control KnobTo Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation Ignitor Button Control Knob Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceODS/PILOT and Burner Replacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Gas leak. See Warning Statement aboveStatement on Optional Positioning Thermostat Sensing BulbFor Masonry and FACTORY- Built Metal Fireplace Locating Thermostat Sensing Specifications AccessoriesEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Winchester OAK ModelsIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.