Desa CLD3924NTB, CLD3018PTA, SGS3124NA Optional Positioning Thermostat Sensing Bulb, Statement on

Page 28

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater shuts off in use (ODS op-

1.

Not enough fresh air is avail-

1.

Open window and/or door for

erates)

 

able

 

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

 

pane/LP gas company

 

3.

ODS/pilot

is partially

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

 

and Maintenance, page 23)

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks (see

is in OFF position

 

statement on page 27

 

Checking Gas Connections,

 

 

 

 

 

page 15)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and re-

 

 

trol valve and burner

 

move foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks (see

 

 

statement on page 27

 

Checking Gas Connections,

 

 

 

 

 

page 15)

 

 

 

 

 

 

Log set cycles to pilot, but room

1.

Thermostat

sensing bulb

1.

Reposition thermostat sensing

temperature drops to a lower than

 

needs to be repositioned

 

bulb (see Optional Positioning

ideal level before log set comes

 

 

 

 

of Thermostat Sensing Bulb,

back on

 

 

 

 

page 28

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

FOR MASONRY AND FACTORY- BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem- perature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fire- place applications. For positioning the thermostat sensing bulb elsewhere, an adhesive-backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

1.Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 34).

2.With 1/4" hex driver or socket, loosen the ther- mostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 36, page 29).

Note: Do not remove the screw. Make sure you tighten the screw after removing the ther- mostat sensing bulb.

IMPORTANT: Do not force or bend the ther- mostat sensing bulb or capillary.

Gas Valve

Assembly

Mounting

BracketThermostat

Sensing Bulb

Figure 34 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 35 - Adhesive-backed Mounting

Clip

28

www.desatech.com

113101-01A

Image 28
Contents 24 Variable MANUALLY-CONTROLLED Models Patent PendingTable of Contents Safety Information Product Identification Product Features Local CodesUnpacking AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsLog Size Side Wall Ceiling Check GAS TypeMinimum Firebox Size Material Requirements for Distance a Safe Installation Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance when Using a HoodDetermining Minimum Mantel Clearance Minimum Mantel Clearances When Using Hood Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyChimney Minimum Permanent Diameter ins Area sq. insConnecting to GAS Supply Installation Items NeededNatural Propane/LPTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater Gas Connections Installing Back LogInstalling Crossover Logs Operating Heater What to do if YOU Smell GASLighting Instructions Ignitor Button Control KnobVariable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Ignitor Button Control Knob Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesODS/PILOT and Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Service Hints Technical ServiceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Gas leak. See Warning Statement aboveFor Masonry and FACTORY- Built Metal Fireplace Optional Positioning Thermostat Sensing BulbStatement on Locating Thermostat Sensing Specifications AccessoriesEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Winchester OAK ModelsIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.