Desa CLD3924NTB, CLD3018PTA, SGS3124NA, CGS3124PA, CGS2718NA, CGS2718PA Ignitor Button Control Knob

Page 21

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or win- dow to vent smell. This will only last a few hours.

Note: Home owners generally prefer to oper- ate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22.

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level be- tween HI and LO.

CAUTION: Do not try to ad- just h eating levels by using the equipment shutoff valve.

WARNING:Damperhandlewill be hot if heater has been running.

1.STOP! Read the safety information, page 20, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 20, column 2. If you don’t smell gas, go to the next step.

Ignitor Button Control Knob

Figure 28 - Control Knob and Ignitor

Button Location

Pilot Burner

Ignitor

Electrode

Thermocouple

 

Propane/LP

Natural Gas

Figure 29 - Pilot

113101-01A

www.desatech.com

21

Image 21
Contents Patent Pending 24 Variable MANUALLY-CONTROLLED ModelsTable of Contents Safety Information Product Identification Local Codes Product FeaturesUnpacking AIR for Combustion VentilationUnusually Tight Construction Determining FRESH-AIR Flow for Fireplace LocationConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Log Size Side Wall CeilingMinimum Firebox Size Minimum Noncombustible Material Clearances Material Requirements for Distance a Safe InstallationDetermining Minimum Mantel Clearance when Using a Hood Mantel ClearancesDetermining Minimum Mantel Clearance Floor Clearances Minimum Mantel Clearances When Using HoodInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Diameter ins Area sq. insInstallation Items Needed Connecting to GAS SupplyPropane/LP NaturalChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Installing Back Log Pressure Testing Heater Gas ConnectionsInstalling Crossover Logs What to do if YOU Smell GAS Operating HeaterIgnitor Button Control Knob Lighting InstructionsManual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Ignitor Button Control Knob Thermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance ODS/PILOT and BurnerBurner Injector Holder and Pilot AIR Inlet Hole Technical Service Service HintsReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Statement above Gas leak. See WarningOptional Positioning Thermostat Sensing Bulb For Masonry and FACTORY- Built Metal FireplaceStatement on Locating Thermostat Sensing Accessories SpecificationsEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Variable MANUALLY-CONTROLLED Winchester OAK Models Parts ListIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS Fireplace

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.