Desa CLD3018PTA, CLD3924NTB, SGS3124NA, CGS3124PA, CGS2718NA, CGS2718PA Locating Thermostat Sensing

Page 29

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

Continued

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sensing bulb, but do not mount sens- ing bulb until step 4. If you have a masonry fire- place, see Figure 37 for location. If you have a factory-built metal fireplace, see Figure 38 for location. If your fireplace has glass doors, posi- tion sensing bulb directly behind door gap on right bottom side (see Figure 39).

4.The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capillary. Once you have decided on a lo- cation, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new lo- cation so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 40). Slide the thermo- stat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Capillary Thermostat Screw

Thermostat

Sensing Bulb

Adhesive-backed

Mounting Clip

Figure 38 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace

Thermostat

Sensing Bulb

Adhesive- backed Mounting Clip

Glass Doors

 

Figure 39 - Installing Thermostat

Retaining

Sensing Bulb behind Glass Doors

 

 

Clamp

 

 

 

Thermostat

 

Thermostat

Sensing Bulb

 

 

 

Sensing Bulb

 

 

Figure 36 - Removing Thermostat

 

 

Sensing Bulb

 

Adhesive-

 

Capillary

 

backed

 

 

Thermostat

 

Mounting Clip

Sensing Bulb

 

 

 

 

Do Not Crimp

 

 

Capillary

Adhesive-backed

Figure 40 - Positioning the Thermostat

Mounting Clip

Sensing Bulb in the Vertical Position

 

Figure 37 - Locating Thermostat Sensing

with the Capillary at the Bottom

 

 

Bulb on Masonry Fireplace

 

 

113101-01A

www.desatech.com

29

Image 29
Contents Patent Pending 24 Variable MANUALLY-CONTROLLED ModelsTable of Contents Safety Information Product Identification Local Codes Product FeaturesUnpacking AIR for Combustion VentilationUnusually Tight Construction Determining FRESH-AIR Flow for Fireplace LocationConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeLog Size Side Wall Ceiling Minimum Noncombustible Material Clearances Material Requirements for Distance a Safe InstallationDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Floor Clearances Minimum Mantel Clearances When Using HoodInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Diameter ins Area sq. insInstallation Items Needed Connecting to GAS SupplyPropane/LP NaturalTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Installing Back Log Pressure Testing Heater Gas ConnectionsInstalling Crossover Logs What to do if YOU Smell GAS Operating HeaterIgnitor Button Control Knob Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation Ignitor Button Control Knob Thermostat Control Operation Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceODS/PILOT and Burner Replacement Parts Technical ServiceService Hints Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Statement above Gas leak. See WarningStatement on Optional Positioning Thermostat Sensing BulbFor Masonry and FACTORY- Built Metal Fireplace Locating Thermostat Sensing Accessories SpecificationsEquipment Shutoff Valve GA5010 Fireplace HoodParts Central Illustrated Parts Breakdown Variable MANUALLY-CONTROLLED Winchester OAK Models Parts ListIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.