Desa CLD3018PTA, CLD3924NTB Inspecting Burners, Thermostat Control Operation, Pilot Flame Pattern

Page 22

OPERATING HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PI-

LOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat out- put and flame height from higher to lower set- tings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions on page 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 21.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 30 shows a correct pilot flame pattern. Fig- ure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 31

turn heater off (see To Turn Off Gas to Appli- ance, page 20 [manually-controlled models] or page 22 [thermostatically-controlled model])

see Troubleshooting, page 25

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Pilot Burner

Thermocouple

 

Propane/LP

Natural Gas

Figure 30 - Correct Pilot Flame Pattern

Pilot Burner

Pilot Burner

Thermocouple

Propane/LP

Natural Gas

Figure 31 - Incorrect Pilot Flame Pattern

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust or lint. Periodi- cally inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running.All slotted burner flame holes should be open with yellow flame present.All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

22

www.desatech.com

113101-01A

Image 22
Contents 24 Variable MANUALLY-CONTROLLED Models Patent PendingTable of Contents Safety Information Product Identification Unpacking Product FeaturesLocal Codes AIR for Combustion VentilationConfined Space and Unconfined Space Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsLog Size Side Wall Ceiling Check GAS TypeMinimum Firebox Size Material Requirements for Distance a Safe Installation Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance when Using a HoodDetermining Minimum Mantel Clearance Minimum Mantel Clearances When Using Hood Floor ClearancesChimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Diameter ins Area sq. insConnecting to GAS Supply Installation Items NeededNatural Propane/LPTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater Gas Connections Installing Back LogInstalling Crossover Logs Operating Heater What to do if YOU Smell GASLighting Instructions Ignitor Button Control KnobVariable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Ignitor Button Control Knob Pilot Flame Pattern Inspecting BurnersThermostat Control Operation Burner Primary AIR HolesODS/PILOT and Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Service Hints Technical ServiceReplacement Parts Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Gas leak. See Warning Statement aboveFor Masonry and FACTORY- Built Metal Fireplace Optional Positioning Thermostat Sensing BulbStatement on Locating Thermostat Sensing Equipment Shutoff Valve GA5010 SpecificationsAccessories Fireplace HoodParts Central Illustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Winchester OAK ModelsIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Royal English OAK Model Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

CGS2718PA, CGS2718NA, CGS3124PA, CGS3124NA, SGS3124PA, SGS3124NA, CLD3018PTA, CLD3018NTA, CLD3924PTB, CLD3924NTB, CGS3124PA, CLD3924NTB, CLD3018PTA, CGS2718PA specifications

Desa CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB are part of the prestigious lineup from Desa, renowned for their high-quality heating solutions. These models combine modern design with advanced technologies, ensuring efficient heating for various residential applications.

The CGS2718NA and CGS2718PA stand out for their compact size and versatile functionality. Both feature a stylish design that seamlessly blends with various home decors. Equipped with advanced infrared heating technology, these models deliver efficient warmth without the need for extensive ventilation. They are ideal for supplemental heating in rooms, offering quick warmth to specific areas while maintaining energy efficiency.

Next in line is the SGS3124NA, a model that takes comfort to the next level with its robust heating capacity. This unit is engineered with durable construction and user-friendly controls, allowing homeowners to easily adjust the temperature according to their preferences. Its ceramic heating elements provide an even heat distribution, ensuring that every corner of the room is warmed efficiently. This model is particularly suited for larger spaces, making it a popular choice for living rooms or open-concept areas.

The CLD3018PTA offers a unique combination of aesthetics and functionality. With various finishes and designs, it can seamlessly enhance the ambience of any space. The unit employs innovative thermal technology that helps reduce energy consumption while maximizing heat output. Integrated safety features, including overheat protection and an automatic shut-off function, provide peace of mind for families.

Lastly, the CLD3924NTB is designed for those seeking a high-performance heating solution. This model boasts an impressive heating capacity suitable for larger areas, making it perfect for homes with high ceilings or expansive layouts. The advanced control panel allows for precise temperature settings, and its quiet operation ensures that comfort is maintained without disruption.

Overall, these Desa models—CGS2718NA, SGS3124NA, CGS2718PA, CLD3018PTA, and CLD3924NTB—serve as an excellent investment for homeowners looking to enhance their comfort and efficiency. With a range of features, innovative technologies, and stylish designs, they cater to diverse heating needs, ensuring warmth and satisfaction in every home.