Desa N15G, TT30G, SPC-30RG, SPC-15RG, HD30G, HD15G owner manual Safety Information, Asphyxiation Hazard

Page 3

SAFETY INFORMATION

WARNING: This product con- tainsand/orgenerateschemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

WARNING: Not for home or recreational vehicle use.

WARNING: Fire, burn, inhala- tion, and explosion hazard. Keep solidcombustibles,suchasbuild- ingmaterials,paperorcardboard, a safe distance away from the heater as recommended by the instructions.Neverusetheheater inspaceswhichdoormaycontain volatileorairbornecombustibles, orproductssuchasgasoline,sol- vents,paintthinner,dustparticles or unknown chemicals.

ASPHYXIATION HAZARD

Do not use this heater for heating human living quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be obstructed.

Proper ventilation air must be provided to support the combustion air require- ments of the heater being used.

Refer to the specification section of the heater’s manual, heater data plate, or contact DESA Heating Products to determine combustion air ventilation requirements of the heater.

Lack of proper ventilation air will lead to improper combustion.

Improper combustion can lead to car- bon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.

1.Keep children and animals away from heater.

2.Never operate heater while sleeping or unat- tended.

3.Check the heater thoroughly for damage. Do not operate a damaged heater.

4.Do not modify the heater or operate a heater which has been modified from its original condition.

5.Use only propane/LP gas.

6.Use only vapor withdrawal propane/LP supply. If there is any question about vapor withdrawal, ask your propane/LP dealer.

7.For outdoor use only. Area must be well ventilated. Provide minimum openings of 1 sq ft (0.093m²) near the floor and 1 sq ft. (0.093m²) near the ceiling. Do not use inside house, camper, tent, vehicle, or any type of unvented or enclosed area.

8.Do not use heater in basement or below ground level.

9.Before connecting heater to the propane/LP tank, make sure the heater regulator knob is in the "OFF" position. Always connect and light heater in areas free of open flames.

10.Mount the propane/LP cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.

11.IMPORTANT: Use only the hose and regulator assembly provided with the dual burner tank top heater. Inspect the hose assembly before each use. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater. The hose and regulator must be protected from damage.

12.The heater burner must be at least 2 ft. (0.61m) above the floor. Always attach to propane/LP tank in an upright position. Never operate a heater on its side or attach to propane/LP tank in a horizontal position. This could lead to dangerous flare-ups or fire. Do not direct heat toward propane/LP cylinders.

13.Maintain minimum clearance from nor- mal combustible materials (like paper) as follows: Sides - 3 ft. (0.91m); Top and Front - 5 ft. (1.5m). Locate 10 ft. (3m) from canvas or plastic tarpaulins or similar cover- ings and secure them to prevent flapping or movement due to wind action.

14.If at any time gas odor is detected, IMME- DIATELY DISCONTINUE operation until the source of gas has been located and cor- rected.

117240-01B

www.desatech.com

3

Image 3
Contents SPC-30RG, HD30G and TT30G For Your SafetyCarbon Monoxide Hazard Models SPC-15RG, HD15G, N15G and TT15GTable of Contents SpecificationsGeneral Hazard Warning Asphyxiation Hazard Safety Information30,000 BTU Models only Assembly InstructionsTo Start Heater Operating InstructionsSecurely close valve on the propane/LP cylinder Maintenance StorageTo Stop Heater To Restart HeaterParts not Under Warranty Technical ServiceReplacement Parts Parts Under WarrantyModels Illustrated Parts BreakdownSPC-15RG, HD15G, N15G, TT15G Parts ListKeep this Warranty Warranty and Repair ServiceSPC-30RG, HD30G Y TT30G Para SU SeguridadAdvertencia Modelos15,000 BTU/HR Modelos Advertencia General DE PeligroTabla DE Contenido EspecificacionesUtilice únicamente gas propano o LP Peligro DE AsfixiaSólo Para Modelos DE 30,000 BTU Instrucciones DE EnsamblajePara Encender EL Calentador Instrucciones DE FuncionamientoMantenimiento Y Almacenamiento Para Apagar EL CalentadorPara Volver a Encender EL Calentador Piezas CON Garantía ReparacionesServicio Técnico Piezas DE RepuestoClasificación Ilustrada DE Piezas Lista DE Piezas Guarde Esta Garantía Garantía Y Servicio DE ReparaciónSPC-30RG, HD30G ET TT30G Risque D’EMPOISONNEMENT AU MO- Noxyde DE CarboneModèles TT15G15 000 BTU/HR Modèles Avertissement DE Risque GénéralTable DES Matières SpécificationsLA Sécurité Risque D’ASPHYXIENʼutilisez que du gaz propane ou du GPL Modèles À 30 000 BTU Uniquement Instructions ’ASSEMBLAGEFixez fermement tous les raccords de gaz Pour Allumer L’APPAREIL DE ChauffageEntretien ET Entreposage Pour Arrêter L’APPAREIL DE ChauffagePour Redémarrer L’APPAREIL DE Chauffage Pièces Sous Garantie Service TechniqueRéparation Pièces DE RechangeModèles SPC-30RG, HD30G ET TT30G VUE Détaillée DES PiècesModèles SPC-15RG, HD15G ET TT15G Liste DES Pièces117240-01B 117240-01B Conservez Cette Garantie Service DE Garantie ET DE Réparation