Desa SL18PT Installation Items, Locating Heater, This heater is designed to be mounted on a wall

Page 8

INSTALLATION

Continued

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

for propane/LP gas, external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

for natural gas, test gauge connection*

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design- certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 23.

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5. If high hu- midity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling and joining wall.

WARNING: Never install the heater

in a bathroom or a bedroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 36 inches (92 cm) from the front, top or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches (45.7 cm) above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspec- tion and service

in coldest part of room

Locate heater near a 120V 60Hz electrical outlet (normal household voltage).

 

CEILING

6" (15.2 cm)

36"

Minimum

(91.4 cm)

Minimum

From

 

Sides Of

 

Heater

 

Left

Right

Side

Side

 

Minimum To

 

Top Surface

 

Of Carpeting,

FLOOR

2" (5.1 cm)Tile Or Other

Combustible

 

Material

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

8

www.desatech.com

116292-01A

Image 8
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Features Local CodesProduct Identification UnpackingAIR for Combustion Ventilation Providing Adequate VentilationFollowing are excerpts from National Fuel Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingThis heater is designed to be mounted on a wall Installation ItemsLocating Heater Installing Heater to Wall Attaching Mounting Bracket To Wall Is provided with heaterFor attaching mounting bracket to wall studs Placing Heater On Mounting BracketConnecting to GAS Supply Installing Bottom Mounting ScrewsImportant For natural gas, check gas line Tor damage could occurPropane/LP Checking GAS ConnectionsMin. Natural Gas Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaEquipment Open Shutoff Valve Closed Gas Meter EquipmentConnecting to Electrical Supply For Your Safety Read Before LightingOperating Heater Extension CordLighting Instructions To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterManual Lighting Procedure Inspecting HeaterBurner Flame Pattern Pilot Flame PatternCleaning Maintenance Pilot Assembly Pilot Air InletODS/PILOT and Burner Burner Pilot AIR InletTroubleshooting Observed Problem Possible Cause RemedyGoes out when control knob is Control knob not pressed Delayed ignition of burner Manifold pressure is too lowBurner orifice is clogged Clean burner see Cleaning ODS/pilot lights but flameWalls or furniture Cleaners, etc. may turn into No power to electric outlet 60Hz outletSlight smoke or odor during Air passageways on heaterMent above LSL18NT, SL18NT and VSL18NT LSL18PT, SL18PT and VSL18PT SpecificationsWiring Diagrams Accessories Technical ServiceReplacement Parts Service Publications Service HintsIllustrated Parts Breakdown Models LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT and VSL18PTParts List Parts Centrals 116292-01A Warranty Information Keep this WarrantyModel Serial No Date of Purchase Industrial Drive P.O. Box Patent PendingQUÉ Hacer SI Percibe Olor a GAS Tabla DE Contenido Información DE Seguridad Información DE Códigos LocalesDesempaque Características DEL ProductoAire Para Combustión Ventilación Cómo Proveer LA Ventilación AdecuadaConstrucción inusualmente sellada Espacio confinado y no confinadoAire Para Ventilación Aire del interior de la construcción para ventilaciónAire del exterior para ventilación InstalaciónVerifique EL Tipo DE GAS Este calentador está diseñado para montarse en una pared Artículos DE InstalaciónUbicación DEL Calentador Instalación DEL Calentador EN LA Pared Soporte de montajeDesmontaje del panel anterior del calentador Panel de vidrio Separador TornilloZando una broca de 9/64 de pulgada Con los orificios que perforó en la paredEn los maderos de la pared Doble el anclaje de pared como se muestra en la figuraConexión AL Suministro DE GAS Instalación de los tornillos de montaje inferioresQuite el calentador del soporte de montaje Calentador Pared SeparadorUnión T Unión terminal Buje reduc Tor a 1/8De pulgada Válvula de Con rosca Cierre del Tipo NPT Tapón EquipoCierre de Equipo Cerrada MedidorDe gas Tanque de suministro de propano o gas LP Válvula deFuncionamiento DEL Calentador Conexión a LA Alimentación EléctricaCable DE Extensión Para SU SEGURIDAD, LEA Esto Antes DE EncenderloApague el piloto Funcionamiento DELInstrucciones DE Encendido Funcionamiento DEL Patrón DE LA Llama DELCalentador Procedimiento DELimpieza Y Mantenimiento Piloto CON ODS Y QuemadorEntrada DE Aire AL Piloto DEL Quemador GabineteSolución DE Problemas Problema Observado Causa Posible RemedioLa posición del regulador de gas no es la correcta Reemplace el regulador de gasCausa Posible Remedio El problema desaparecerá Hay aire en la línea de gas Hasta que se elimine el aireLínea de gas Los conductos de aire en elCia anterior Diagramas DE Cableado EspecificacionesLSL18NT, SL18NT y VSL18NT LSL18PT, SL18PT y VSL18PTAccesorios Servicio TécnicoPublicaciones DE Servicio Piezas DE RepuestoClasificación Ilustrada DE Piezas Modelos LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT Y VSL18PTLista DE Piezas Laporte’s Parts & Service 2444 N th Street Centrales DE PiezasNotas Información DE Garantía Guarde Esta Garantía