Desa VGC18NR/PR Mantel Clearances, Material Requirements for Distance a Safe Installation

Page 10

Installation

Continued

NOTICE: Manual control heaters maybeusedasaventedproduct. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 12.

Minimum Noncombustible Material

Clearances

If Not Using Mantel

Note: If using a mantel proceed to If Using Mantel. If not using a mantel, follow these instructions. You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have non- combustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" Models Only). See Figure 5 for minimum clearances.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have non- combustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" Models Only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7, page 11, for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 12.

Noncombustible

 

 

 

 

Material

Requirements for

Distance (A)

Safe Installation

12" or more

Noncombustible mate-

 

rial OK.

Between 8" and 12"

24" or 30" Models:

 

Install fireplace hood

 

accessory (GA6050,

 

GA6052 or GA6053 see

 

Accessories, page 33).

 

18" Model: Noncombus-

 

tible material OK.

Less than 8"

Noncombustible mate-

 

rial must be extended to

 

at least 8". See Between

 

8" and 12", above. If you

 

cannot extend material,

 

you must operate heater

 

with flue damper open.

 

 

 

 

Heat Resistant

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

(A)

 

 

 

 

 

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

Mantel Clearances

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6, page 11).

Determining Minimum Mantel Clearance

When Using a Hood

If minimum clearances in Figure 6, page 11, are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7, page 11, when using hood.

10

www.desatech.com

119162-01A

Image 10
Contents Patent Pending Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRAlso Design-Certified As Vented Decorative Appliances Table of Contents Safety InformationSafety Information Safety Information Local Codes Product FeaturesProduct Identification UnpackingProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsFor Vent-Free Operation Installation and ClearancesCheck GAS Type Minimum Firebox SizeDetermining Minimum Mantel Clearance When Using a Hood Material Requirements for Distance a Safe InstallationMantel Clearances Floor Clearances Log SetArea of Various Standard Round Flues Diameter Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Chimney Minimum PermanentConnecting to GAS Supply Installation Items NeededDealer. See Accessories, NaturalChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater Gas Connections Installing optional remote accessoriesInstalling Remote Receiver Installing Switch Installing LOGS, Embers and Lava RockInstalling Log #1 Operating Heater For Your Safety Read Before LightingLighting Instructions Control Knob, Ignitor Button AUTO/OFF/ON Switch Optional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationThermostat Series Model HRC200 Pilot Flame Pattern Wiring DiagramInspecting Burners Front Burner Flame PatternLogs Cleaning MaintenanceBurner Injector Holder Pilot Air Inlet Hole Main burnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Slight smoke or odor during Gas leak. See Warning See Checking Gas ConnecTechnical Service SpecificationsService Hints Replacement PartsRemote-Ready Variable Control Models Illustrated Parts BreakdownVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Information video Cleaning KIT GCKLava Rock GA6060 Fire Crackle CF6-A119162-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters