9.Connect wires from hardware pack (with remote receiver bracket) to control valve at the TPTH and TH locations as shown in Figure 20. Connect other ends of these wires to remote receiver wires. Note: Make sure excess wire does not interfere with burner or pilot.

10.If heater was removed from fireplace before installation of remote accessory, see Installing Heater Base Assembly on page 12 to reinstall heater into fireplace. Test gas connection for leaks (see Checking Gas Connections, page 15).

11.If logs were removed from heater for install remote accessory, replace logs (see Installing Logs, Embers and Lava Rock, page 17).

Red Wire to

Red Wire on

Receiver

White Wire to

Control Valve White Wire on Receiver

Figure 20 - Connecting Wires

Installing Batteries for Remote Receiver

and Hand Held Remote Control

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver behind receiver bracket mounted on base assembly.

2.Locate the battery clip mounted on the back of the receiver (see Figure 18, page 16).

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Installing 9-Volt Battery (Not Included) in Hand-

Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Battery Cover

Terminal

Wires

 

 

Remote

9-Volt Battery

Battery

Control

Housing

Unit

Figure 21 - Installing Battery in Hand-Held

Remote Control Unit

Installing Switch

The AUTO/OFF/ON switch for this log set will need to be installed into the small single log ac- companying this log set.

1.Slip wires of switch assembly through hole in center of log (see Figure 22).

2.Snap switch assembly into place.

3.Attach wires to control valve as shown in Figure 20.

Switch

Figure 22 - Installing AUTO/OFF/ON

Switch

INSTALLING LOGS, Embers and Lava Rock

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place rear log on bas assembly as shown in Fig- ure 23, page 18. The log will fit over right end of burner and rest in the middle of U-burner.

119162-01A

www.desatech.com

17

Image 17
Contents Also Design-Certified As Vented Decorative Appliances Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRPatent Pending Safety Information Table of ContentsSafety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingDetermining FRESH-AIR Flow for Heater Location Air For Combustion VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and ClearancesFor Vent-Free Operation Minimum Firebox SizeMantel Clearances Material Requirements for Distance a Safe InstallationDetermining Minimum Mantel Clearance When Using a Hood Log Set Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationArea of Various Standard Round Flues Diameter Chimney Minimum PermanentInstallation Items Needed Connecting to GAS SupplyNatural Dealer. See Accessories,Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsInstalling Remote Receiver Installing optional remote accessoriesPressure Testing Heater Gas Connections Installing LOGS, Embers and Lava Rock Installing SwitchInstalling Log #1 Lighting Instructions For Your Safety Read Before LightingOperating Heater Control Knob, Ignitor Button AUTO/OFF/ON Switch To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Inspecting Burners Wiring DiagramPilot Flame Pattern Front Burner Flame PatternBurner Injector Holder Pilot Air Inlet Hole Cleaning MaintenanceLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Slight smoke or odor during See Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Illustrated Parts BreakdownRemote-Ready Variable Control Models Parts List Illustrated Parts Breakdown and Parts List Accessories Lava Rock GA6060 Cleaning KIT GCKInformation video Fire Crackle CF6-A119162-01A Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty