Desa VGC18NR/PR Specifications, Service Hints, Technical Service, Replacement Parts

Page 29

Specifications

Remote-Ready MODELS

VGC18Pr

Rating (Variable): 24,000/30,000 Btu/Hr

Type Gas: Propane/LP

Ignition: Electronic

Manifold Pressure: 7.9" W.C.

Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

vgc18Nr

Rating (Variable): 21,000/30,000 Btu/Hr

Type Gas: Natural

Ignition: Electronic

Manifold Pressure: 3.4" W.C.

Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.

VGC24PR

Rating (Variable): 25,000/36,000 Btu/Hr

Type Gas: Propane/LP

Ignition: Electronic

Manifold Pressure: 7.9" W.C.

Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

VGC24NR

Rating (Variable): 25,000/36,000 Btu/Hr

Type Gas: Natural

Ignition: Electronic

Manifold Pressure: 3.4" W.C.

Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.

*For purpose of input adjustment

VGC30PR

Rating (Variable): 25,000/36,000 Btu/Hr

Type Gas: Propane/LP

Ignition: Electronic

Manifold Pressure: 7.9" W.C.

Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.

VGC30NR

Rating (Variable): 25,000/36,000 Btu/Hr

Type Gas: Natural

Ignition: Electronic

Manifold Pressure: 3.4" W.C.

Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.

*For purpose of input adjustment

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, con- tact your local propane/LP or natural gas supplier.

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’techni- cal services web site at www.desatech.com.

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Technical Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

119162-01A

www.desatech.com

29

Image 29
Contents Also Design-Certified As Vented Decorative Appliances Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRPatent Pending Safety Information Table of ContentsSafety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingDetermining FRESH-AIR Flow for Heater Location Air For Combustion VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and ClearancesFor Vent-Free Operation Minimum Firebox SizeMantel Clearances Material Requirements for Distance a Safe InstallationDetermining Minimum Mantel Clearance When Using a Hood Log Set Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationArea of Various Standard Round Flues Diameter Chimney Minimum PermanentInstallation Items Needed Connecting to GAS SupplyNatural Dealer. See Accessories,Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsInstalling Remote Receiver Installing optional remote accessoriesPressure Testing Heater Gas Connections Installing LOGS, Embers and Lava Rock Installing SwitchInstalling Log #1 Lighting Instructions For Your Safety Read Before LightingOperating Heater Control Knob, Ignitor Button AUTO/OFF/ON Switch To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Inspecting Burners Wiring DiagramPilot Flame Pattern Front Burner Flame PatternBurner Injector Holder Pilot Air Inlet Hole Cleaning MaintenanceLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Slight smoke or odor during See Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Illustrated Parts BreakdownRemote-Ready Variable Control Models Parts List Illustrated Parts Breakdown and Parts List Accessories Lava Rock GA6060 Cleaning KIT GCKInformation video Fire Crackle CF6-A119162-01A Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty