Product
Identification
Electronic
Ignitor
Chassis
| Glowing |
| |
| Embers |
| |
| Flame | Control | |
Remote | Adjustment | ||
Knob | |||
Control | Knob | AUTO/ | |
(Optional) |
| ||
|
| OFF/ON | |
|
| Switch |
Figure 1 - Product Identification
Local Codes
Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269Optional Remote Control
Accessories
There are four optional remote controls that | |||
can be purchased separately for | |||
Models Only: |
|
| |
• | wall switch | • | |
• | wall thermostat | • |
See Accessories, page 42.
The wall thermostat or
Unpacking
CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain important warranty and safety information.
1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base as- sembly by burners. This could damage heater. Always handle base assembly by grate.
2.Remove all protective packaging applied to logs and heater for shipment.
3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.
Product Features
Operation
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing coals. This heater is designed for
Safety Device
This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for
Electronic Ignition System
This heater has an electronic ignitor to light heater fuel supply.