Desa VGC18NR/PR Cleaning Maintenance, Burner Injector Holder Pilot Air Inlet Hole, Logs

Page 24

Cleaning and

Maintenance

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

Burner Injector Holder and

Pilot Air Inlet Hole

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 38).

3.Blow air through the ports/slots and holes in the burner.

Injector

Holder

Burner

Tube

Primary Air

Inlet Holes

Figure 38 - Injector Holder On Outlet

Burner Tube

Pilot Air

Inlet Hole

Pilot Assembly

Figure 39 - Pilot Inlet Air Hole (Your pilot

may vary from pilot shown)

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 39). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

LOGS

If you remove logs for cleaning, refer to Install- ing Logs Embers and Lava Rock, page 18, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

main burner

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

24

www.desatech.com

119162-01A

Image 24
Contents Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PR Patent PendingAlso Design-Certified As Vented Decorative Appliances Table of Contents Safety InformationSafety Information Safety Information Product Features Product IdentificationLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation and Clearances Check GAS TypeFor Vent-Free Operation Minimum Firebox SizeMaterial Requirements for Distance a Safe Installation Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor Clearances Log SetInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyArea of Various Standard Round Flues Diameter Chimney Minimum PermanentConnecting to GAS Supply Installation Items NeededDealer. See Accessories, NaturalChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling optional remote accessories Pressure Testing Heater Gas ConnectionsInstalling Remote Receiver Installing Switch Installing LOGS, Embers and Lava RockInstalling Log #1 For Your Safety Read Before Lighting Operating HeaterLighting Instructions Control Knob, Ignitor Button AUTO/OFF/ON Switch Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Wiring Diagram Inspecting BurnersPilot Flame Pattern Front Burner Flame PatternCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleLogs Main burnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Slight smoke or odor during Gas leak. See Warning See Checking Gas ConnecSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Remote-Ready Variable Control ModelsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Cleaning KIT GCK Lava Rock GA6060Information video Fire Crackle CF6-A119162-01A Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters