Desa VGC18NR/PR installation manual Gas leak. See Warning, See Checking Gas Connec

Page 28

Troubleshooting

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from paint,

1.

Open window to ventilate

odors

 

hair spray, glues, cleaners, chemi-

 

room. Stop using odor caus-

 

 

cals, new carpet, etc. (See IM-

 

ing products while heater is

 

2.

PORTANT statement above)

2.

running

 

Low fuel supply (propane/LP

Refill supply tank (propane/LP

 

3.

only)

3.

only)

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

2.

able

2.

ventilation

 

Low line pressure

Contact local natural or pro-

 

3.

ODS/pilot is partially clogged

3.

pane/LP gas company

 

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 26)

 

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve or gas control

2.

tions, page 16)

 

Replace control valve or gas

 

 

defective

 

control

 

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

2.

trol valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

 

 

 

 

 

Log set cycles to pilot, but room

1.

Hand-held remote control is

1.

Move hand-held remote con-

temperature drops to a lower

 

too close to heater

 

trol unit farther away from the

than ideal level before log set

 

 

 

heater

comes back on

 

 

 

 

 

28

www.desatech.com

119162-01A

Image 28
Contents Patent Pending Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRAlso Design-Certified As Vented Decorative Appliances Table of Contents Safety InformationSafety Information Safety Information Product Features Product IdentificationLocal Codes UnpackingProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation and Clearances Check GAS TypeFor Vent-Free Operation Minimum Firebox SizeDetermining Minimum Mantel Clearance When Using a Hood Material Requirements for Distance a Safe InstallationMantel Clearances Floor Clearances Log SetInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyArea of Various Standard Round Flues Diameter Chimney Minimum PermanentConnecting to GAS Supply Installation Items NeededDealer. See Accessories, NaturalChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater Gas Connections Installing optional remote accessoriesInstalling Remote Receiver Installing Switch Installing LOGS, Embers and Lava RockInstalling Log #1 Operating Heater For Your Safety Read Before LightingLighting Instructions Control Knob, Ignitor Button AUTO/OFF/ON Switch Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationThermostat Series Model HRC200 Wiring Diagram Inspecting BurnersPilot Flame Pattern Front Burner Flame PatternCleaning Maintenance Burner Injector Holder Pilot Air Inlet HoleLogs Main burnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Slight smoke or odor during Gas leak. See Warning See Checking Gas ConnecSpecifications Service HintsTechnical Service Replacement PartsRemote-Ready Variable Control Models Illustrated Parts BreakdownVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Cleaning KIT GCK Lava Rock GA6060Information video Fire Crackle CF6-A119162-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters