Desa VGC18NR/PR installation manual Connecting to GAS Supply, Installation Items Needed

Page 13

Installation

Continued

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose and fittings (not provided) (if allowed by local codes)

• sealant (resistant to propane/LP gas, not pro- vided)

• electric drill with 3/16” masonry drill bit Note: Install optional HRC Series receiver and hand-held remote control kit (see Accessories, page 33) before installing gas log heater. See in- stallation instructions included with the kit.

1.Apply pipe joint sealant lightly to male threads of gas fitting (not provided). Connect approved flexible gas hose to inlet side of gas control (see Figure 11).

2.Position heater base assembly in fireplace.

3.Mark screw locations through holes in front panel of base (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

4.Remove heater base from fireplace.

5.Drill holes at marked locations using 3/16" drill bit.

6.Attach base, through holes in front panel of base, to fireplace floor using masonry screws provided in hardware package (see Figure 12).

7.Connect to gas supply. See Connecting To Gas Supply.

Flexible Gas Hose

Gas Control (if allowed by local codes)

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

Masonry Screw

Figure 13 - Attaching Base to Fireplace

Floor

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

119162-01A

www.desatech.com

13

Image 13
Contents Patent Pending Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRAlso Design-Certified As Vented Decorative Appliances Safety Information Table of ContentsSafety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and ClearancesFor Vent-Free Operation Minimum Firebox SizeDetermining Minimum Mantel Clearance When Using a Hood Material Requirements for Distance a Safe InstallationMantel Clearances Log Set Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationArea of Various Standard Round Flues Diameter Chimney Minimum PermanentInstallation Items Needed Connecting to GAS SupplyNatural Dealer. See Accessories,Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsPressure Testing Heater Gas Connections Installing optional remote accessoriesInstalling Remote Receiver Installing LOGS, Embers and Lava Rock Installing SwitchInstalling Log #1 Operating Heater For Your Safety Read Before LightingLighting Instructions Control Knob, Ignitor Button AUTO/OFF/ON Switch To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 Inspecting Burners Wiring DiagramPilot Flame Pattern Front Burner Flame PatternBurner Injector Holder Pilot Air Inlet Hole Cleaning MaintenanceLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Slight smoke or odor during See Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsRemote-Ready Variable Control Models Illustrated Parts BreakdownVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Lava Rock GA6060 Cleaning KIT GCKInformation video Fire Crackle CF6-A119162-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters