Quadra-Fire MTVERNON-AE-MBK owner manual Installation Operation, Hot glass will cause burns

Page 1

R

MT. VERNON PELLET STOVE

ADVANCED ENERGY (AE)

Owner’s Manual

Installation and

Operation

Models:

MTVERNON-AE-MBK

MTVERNON-AE-PMH

MTVERNON-AE-CSB

MTVERNON-AE-CWL

Tested and

O-T L

Portland

Listed by

Oregon USA

C US

OMNI-Test Laboratories, Inc.

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating and

Read, understand and

Leave this manual with

maintenance instruc-

follow these instruc-

party responsible for use

tions included.

tions for safe installa-

and operation.

 

tion and operation.

 

DO DISCARDNOT

WARNING

Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

Do not overfire - If any external part starts to glow, you are overfiring. Reduce feed rate. Overfiring will void your warranty.

Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

Do not touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

CAUTION

Tested and approved for wood pellets, shelled field corn, wheat and black oil sunflower seeds. Burning of any other type of fuel voids your warranty.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdic- tion about restrictions, installation inspection, and permits.

www.quadrafire.com

7034-106E

September 1, 2008

Image 1
Contents Hot glass will cause burns Installation OperationMfg Date Test Lab & Report No Mt. Vernon Pellet Stove AETable of Contents Listing and Code Approvals Appliance Location Getting StartedNegative Pressure Wall Control ThermostatDraft Tools And Supplies Needed Mt. Vernon Pellet Stove AE Fire SafetyInspect Appliance & Components and Pre-Use Check List Appliance Dimensions 3Dimensions and Clearances76-152mm Adapter To 6 in 76-152mm Offset Adapter Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsVenting Termination Minimum Requirements 4Vent InformationDo not Terminate Vent Termination must exhaust above air inlet elevationEquivalent Feet of Pipe Mt. Vernon Pellet Stove AE Chimney and Exhaust ConnectionExample of 3 Elbow-Rear Vent Termination Calculation See FigureAltitude in Thousands of Feet Mt. Vernon Pellet Stove AE Pipe Selection ChartAlcove 5Venting SystemsDegree Straight OutMt. Vernon Pellet Stove AE Through The Wall Through The Wall & Vertical Exterior Vertical Interior Typical InstallationAlternate Masonry Mt. Vernon Pellet Stove AE Masonry6Mobile Home Installation Leg Leveling System 7Appliance Set-UpOutside Air Kit Instructions Adapter Installation Mt. Vernon Pellet Stove AE Top Vent Adapter InstallationInstalling the Top Vent Adapter Rear Vent and Rear Vent to Top VentPiece LOG SET Installation Back Side of Wall Control with Cover Off Fuel Size, Material and Storage Operating InstructionsFor detailed operating instructions See Wall Control Thermostat ManualStarting Your First Fire Ignition Cycles Battery Back-up System OptionalStart-Up Auto / Man L, ML, M, MH, HAuto / Man L, ML, M, MH, H Cont’d Auto-CleanShutdown Additional Screen MessagesWall Control for Reference Mt. Vernon Pellet Stove AE Quick Start GuideMt. Vernon Pellet Stove AE Quick Start Guide Cont’d Setting Comfort LevelIssues Solutions Mt. Vernon Pellet Stove AE Frequently Asked QuestionsPossible Cause Corrective Action Error MessageCleaning or Inspection Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance WeeksTypes of Fuel Cleaning Ash Pan FrequencyAlternate Fuel Daily See Disposal of Ashes belowCleaning Heat Exchanger & Drop Tube Mt. Vernon Pellet Stove AE Cleaning the Glass Cleaning the HopperCleaning Convection Blower Requires No Lubrication Cleaning the Top Vent Adapter if installedPreparing Firebox for Non-Burn Season High Ash Fuel Content MaintenanceConvection Blower Replacement Combustion Exhaust Blower Replacement Component Functions Reference MaterialsThermocouple Drop Tube Vacuum Switch Power SupplyOverheat Sensor Snap Disc Thermocouple FirepotLeft Side Mt. Vernon Pellet Stove AE Component LocationsDescription Part Number Mt. Vernon Pellet Stove AE Exploded DrawingsMt. Vernon Pellet Stove AE Item No Accessories Mt. Vernon Pellet Stove AE Service Parts and AccessoriesMt. Vernon Pellet Stove AE TOUCHUP-CSB Item No Date of Service Performed By Description of Service Mt. Vernon Pellet Stove AE Service And Maintenance LogDate of Service Performed By Description of Service Mt. Vernon Pellet Stove AE Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Mt. Vernon Pellet Stove AE Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d T O T O