Quadra-Fire MTVERNON-AE-PMH, MTVERNON-AE-MBK, MTVERNON-AE-CWL Convection Blower Replacement

Page 36

R

Mt. Vernon Pellet Stove (AE)

F.Convection Blower Replacement

1.Follow the proper shut down procedures as outlined on page 30, Section 10.A.

2.Remove the left and right side panels by removing the 4 screws using a Phillips head screw driver. Figure 36.1.

3.Depress the tab on the left side and snap out the power supply. You do not need to disconnect any wires.

Figure 36.1.

4.Remove the 2 screws at the bottom of the back panel so there will be room to remove the blower. Figure 36.1

5.Reach behind the blower and release the latch by push- ing the top of the latch towards the blower. Figure 36.2.

6.Rock the top of the blower slightly and lift up. The blower will pass around the control board and out the left side of the appliance.

7.Disconnect the wire harness from the bottom of the blower by depressing the tabs on the sides of the con- nector and then pulling to remove. Figure 36.1.

8.Re-connect wire harness to the new blower.

9.Install replacement blower by placing the bottom flange into the opening first then rotate blower up into posi- tion.

10.When the blower is properly positioned the latch will engage the notch to hold the blower in place. Figure 36.3.

11.Re-secure the back panel, snap the power supply back in and re-secure the side panel(s).

ot h

Lat h

Figure 36.2

Lat h ngaged

Figure 36.3

Remove

Right Side

Panel

epress a and Snap t Po er S ppl

 

Remove

Remove

Left Side

Panel

Screws

 

Disconnect Wire Harness from Bottom of Blower

Figure 36.1

Page 36

7034-106E

September 1, 2008

Image 36
Contents Installation Operation Hot glass will cause burnsMt. Vernon Pellet Stove AE Mfg Date Test Lab & Report NoTable of Contents Listing and Code Approvals Getting Started Appliance LocationWall Control Thermostat Negative PressureDraft Mt. Vernon Pellet Stove AE Fire Safety Tools And Supplies NeededInspect Appliance & Components and Pre-Use Check List 3Dimensions and Clearances Appliance Dimensions76-152mm Adapter To 6 in 76-152mm Offset Adapter Exception for Horizontal Installations Hearth Pad Requirements UL and ULC4Vent Information Venting Termination Minimum RequirementsDo not Terminate Vent Termination must exhaust above air inlet elevationMt. Vernon Pellet Stove AE Chimney and Exhaust Connection Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation See FigureMt. Vernon Pellet Stove AE Pipe Selection Chart Altitude in Thousands of Feet5Venting Systems AlcoveStraight Out DegreeMt. Vernon Pellet Stove AE Through The Wall Vertical Interior Typical Installation Through The Wall & Vertical ExteriorMt. Vernon Pellet Stove AE Masonry Alternate Masonry6Mobile Home Installation 7Appliance Set-Up Leg Leveling SystemOutside Air Kit Instructions Mt. Vernon Pellet Stove AE Top Vent Adapter Installation Adapter InstallationInstalling the Top Vent Adapter Rear Vent and Rear Vent to Top VentPiece LOG SET Installation Back Side of Wall Control with Cover Off Operating Instructions Fuel Size, Material and StorageSee Wall Control Thermostat Manual For detailed operating instructionsStarting Your First Fire Battery Back-up System Optional Ignition CyclesStart-Up Auto / Man L, ML, M, MH, HAuto-Clean Auto / Man L, ML, M, MH, H Cont’dShutdown Additional Screen MessagesMt. Vernon Pellet Stove AE Quick Start Guide Wall Control for ReferenceSetting Comfort Level Mt. Vernon Pellet Stove AE Quick Start Guide Cont’dMt. Vernon Pellet Stove AE Frequently Asked Questions Issues SolutionsError Message Possible Cause Corrective ActionQuick Reference Maintenance Chart Cleaning or Inspection10Maintaining & Servicing Your Appliance WeeksCleaning Ash Pan Frequency Types of FuelAlternate Fuel Daily See Disposal of Ashes belowCleaning Heat Exchanger & Drop Tube Mt. Vernon Pellet Stove AE Cleaning the Hopper Cleaning the GlassCleaning Convection Blower Requires No Lubrication Cleaning the Top Vent Adapter if installedHigh Ash Fuel Content Maintenance Preparing Firebox for Non-Burn SeasonConvection Blower Replacement Combustion Exhaust Blower Replacement Reference Materials Component FunctionsPower Supply Thermocouple Drop Tube Vacuum SwitchOverheat Sensor Snap Disc Thermocouple FirepotMt. Vernon Pellet Stove AE Component Locations Left SideMt. Vernon Pellet Stove AE Exploded Drawings Description Part NumberMt. Vernon Pellet Stove AE Mt. Vernon Pellet Stove AE Service Parts and Accessories Item No AccessoriesMt. Vernon Pellet Stove AE TOUCHUP-CSB Item No Mt. Vernon Pellet Stove AE Service And Maintenance Log Date of Service Performed By Description of ServiceDate of Service Performed By Description of Service Mt. Vernon Pellet Stove AE Homeowner’s Notes Mt. Vernon Pellet Stove AE Warranty Policy CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d T O T O