Mt. Vernon Pellet Stove (AE)
F.Convection Blower Replacement
1.Follow the proper shut down procedures as outlined on page 30, Section 10.A.
2.Remove the left and right side panels by removing the 4 screws using a Phillips head screw driver. Figure 36.1.
3.Depress the tab on the left side and snap out the power supply. You do not need to disconnect any wires.
Figure 36.1.
4.Remove the 2 screws at the bottom of the back panel so there will be room to remove the blower. Figure 36.1
5.Reach behind the blower and release the latch by push- ing the top of the latch towards the blower. Figure 36.2.
6.Rock the top of the blower slightly and lift up. The blower will pass around the control board and out the left side of the appliance.
7.Disconnect the wire harness from the bottom of the blower by depressing the tabs on the sides of the con- nector and then pulling to remove. Figure 36.1.
8.
9.Install replacement blower by placing the bottom flange into the opening first then rotate blower up into posi- tion.
10.When the blower is properly positioned the latch will engage the notch to hold the blower in place. Figure 36.3.
11.
ot h
Lat h
Figure 36.2
Lat h ngaged
Figure 36.3
Remove
Right Side
Panel
epress a and Snap t Po er S ppl
| Remove | |
Remove | Left Side | |
Panel | ||
Screws | ||
|
Disconnect Wire Harness from Bottom of Blower
Figure 36.1
Page 36 | September 1, 2008 |