Mt. Vernon Pellet Stove (AE)

C. Vertical into Existing Class A Chimney

Rain Cap

 

Flashing

 

12 in. (305mm) Minimum

 

Firestop

 

6 in. (152mm) Class A

 

Chimney Connector

 

Adapter

 

Ceiling Support

 

3 in. (76mm) Min.

6 in.

3 to 6 in. (76-152mm)

(152mm)

Offset Adapter

Min.

3 to 3 in.

 

 

(76-76mm)

 

Top Vent Kit

 

Clean-out Cover

Non-combustible Hearth Pad

Figure 15.1

We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred.

All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra-Fire Out- side Air Kit in mobile homes. Single wall pipe is approved for residential installations only.

*NOTE: Clearance to combustibles are for standard pellet pipe. If pellet pipe manufac- turer allows reduced clearances to their pipe, reduced clearances are allowed.

D. Through The Wall & Vertical - Exterior

 

Rain

 

Cap

Flashing

12 in.

(305mm)

 

minimum

2 in. (51mm) minimum

Support

Bracket

 

 

every 60 in.

6 in. (152mm)

(1524mm)

 

minimum

Wall Thimble

 

 

Tee

 

Clean-out

 

Cover

Non-combustible Hearth Pad

Figure 15.2

E. Vertical - Interior - Typical Installation

Rain Cap

 

Flashing

12 in.

 

(305mm)

 

 

 

 

Minimum

 

Firestop

 

6 in.

 

3 in. (76mm)Min.

 

 

(152mm)

 

 

Min.

 

3 in. to 3 in.

 

 

(76-76mm)

 

 

Top Vent Kit

 

 

Clean-out Cover

Non-combustible Hearth Pad

Figure 15.3

September 1, 2008

7034-106E

Page 15

Image 15
Contents Hot glass will cause burns Installation OperationMfg Date Test Lab & Report No Mt. Vernon Pellet Stove AETable of Contents Listing and Code Approvals Appliance Location Getting StartedWall Control Thermostat Negative PressureDraft Mt. Vernon Pellet Stove AE Fire Safety Tools And Supplies NeededInspect Appliance & Components and Pre-Use Check List 3Dimensions and Clearances Appliance Dimensions76-152mm Adapter To 6 in 76-152mm Offset Adapter Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsTermination must exhaust above air inlet elevation 4Vent InformationVenting Termination Minimum Requirements Do not Terminate VentSee Figure Mt. Vernon Pellet Stove AE Chimney and Exhaust ConnectionEquivalent Feet of Pipe Example of 3 Elbow-Rear Vent Termination CalculationAltitude in Thousands of Feet Mt. Vernon Pellet Stove AE Pipe Selection ChartAlcove 5Venting SystemsStraight Out DegreeMt. Vernon Pellet Stove AE Through The Wall Through The Wall & Vertical Exterior Vertical Interior Typical InstallationAlternate Masonry Mt. Vernon Pellet Stove AE Masonry6Mobile Home Installation 7Appliance Set-Up Leg Leveling SystemOutside Air Kit Instructions Rear Vent and Rear Vent to Top Vent Mt. Vernon Pellet Stove AE Top Vent Adapter InstallationAdapter Installation Installing the Top Vent AdapterPiece LOG SET Installation Back Side of Wall Control with Cover Off Fuel Size, Material and Storage Operating InstructionsSee Wall Control Thermostat Manual For detailed operating instructionsStarting Your First Fire Auto / Man L, ML, M, MH, H Battery Back-up System OptionalIgnition Cycles Start-UpAdditional Screen Messages Auto-CleanAuto / Man L, ML, M, MH, H Cont’d ShutdownWall Control for Reference Mt. Vernon Pellet Stove AE Quick Start GuideMt. Vernon Pellet Stove AE Quick Start Guide Cont’d Setting Comfort LevelIssues Solutions Mt. Vernon Pellet Stove AE Frequently Asked QuestionsPossible Cause Corrective Action Error MessageWeeks Quick Reference Maintenance ChartCleaning or Inspection 10Maintaining & Servicing Your ApplianceSee Disposal of Ashes below Cleaning Ash Pan FrequencyTypes of Fuel Alternate Fuel DailyCleaning Heat Exchanger & Drop Tube Mt. Vernon Pellet Stove AE Cleaning the Top Vent Adapter if installed Cleaning the HopperCleaning the Glass Cleaning Convection Blower Requires No LubricationPreparing Firebox for Non-Burn Season High Ash Fuel Content MaintenanceConvection Blower Replacement Combustion Exhaust Blower Replacement Component Functions Reference MaterialsThermocouple Firepot Power SupplyThermocouple Drop Tube Vacuum Switch Overheat Sensor Snap DiscLeft Side Mt. Vernon Pellet Stove AE Component LocationsDescription Part Number Mt. Vernon Pellet Stove AE Exploded DrawingsMt. Vernon Pellet Stove AE Item No Accessories Mt. Vernon Pellet Stove AE Service Parts and AccessoriesMt. Vernon Pellet Stove AE TOUCHUP-CSB Item No Date of Service Performed By Description of Service Mt. Vernon Pellet Stove AE Service And Maintenance LogDate of Service Performed By Description of Service Mt. Vernon Pellet Stove AE Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability Mt. Vernon Pellet Stove AE Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d T O T O