Quadra-Fire 7008-115 Design and Installation Considerations, Tools and Supplies Needed

Page 14

B. Design and Installation Considerations

Quadra-Fire gas inserts are designed for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provin- cial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the ab- sence of local or regional codes, meet criteria of NFPA 211. No additional outside air source is required.

Installation MUST comply with local, regional, state and na- tional codes and regulations. Consult insurance carrier, local building inspector, fire officials or authorities having jurisdic- tion over restrictions, installation inspection and permits.

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fireplace as specified by the professionals.

Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid- fuel fireplaces. In the absence of local or regional codes, refer to NFPA 211.

Ensure all joints are properly engaged and the chimney is properly secured.

Minimum fireplace size. See Section 5.A.

Gas supply piping requirements.

Electrical wiring requirements.

Finishing details.

Whether optional accessories—devices such as a remote control—are desired.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified technician, service agency or your dealer.

C. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Tape measure

Framing material

Pliers

7/16 inch wrench

Hammer

Phillips screwdriver

Gloves

Framing square

Voltmeter

Electric drill and bits (1/4 in.)

Plumb line

Safety glasses

Level

Reciprocating saw

Manometer

Flat blade screwdriver

Noncorrosive leak check solution

1/2 - 3/4 inch length, #6 or #8 Self-drilling screws

Caulking material (300ºF minimum continuous exposure rating)

Stove cement (1200ºF or higher continuous exposure rating)

D. Inspect Appliance and Components

Carefully remove the appliance and components from the packaging.

The vent system components and surround may be shipped in separate packages.

Remove log set and component pack from firebox.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry.

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modification of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

WARNING! Risk of Fire,/Explosion/Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.

14

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

Image 14
Contents Model What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Thermostats and Wall Switches Decorative Doors, Fronts and SurroundsFor Your Safety Read Before Lighting Standing Pilot IgnitionFrequently Asked Questions After Appliance is LitMaintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum fireplace opening requirements are shown in Figure Fireplace Size RequirementsMinimum Fireplace Opening Mantel and Wall Projections HearthTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance Factory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalConverting to LP Gas Gas InformationFuel Conversion Screws Nuts Holding Burner PANValve Regulator Replacement Gas Pressure Gas ConnectionWire Size Max. Length Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationIncluded in kit Blower Blower InstallationTools required Powered Phillips head screwdriver = 1/4 in mm female spade = 1/4 in mm male spade Finishing Clearance to CombustiblesAppliance Setup Tools required Philips head screwdriver Grille InstallationPanel Set Installation Back of TOP Panel Screws Back of Side PanelEmber Placement Placement of EmbersBrick Installation Retaining TabsPositioning the Logs Rear Brick Retaining TabsAir Shutter Adjustment Air shutter is used to fine-tune the flame as necessaryRemoving Fixed Glass Assembly Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference Materials B. Vent Kits Components Direct Vent Flex Liner KitsPart number list on following Log Set AssemblyService Parts Depot Service Parts ListStocked Description Comments Part Number Thermocouple 200-2950 Thermopile 842-0250Contact Information Do not Discard this Manual

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.