Quadra-Fire 7008-115 owner manual Grille Installation, Panel Set Installation

Page 30

F. Grille Installation

Remove the door of appliance. Remove the four screws (two at each end) holding grille in place. Lift up to remove.

Assemble the trim with the two corner brackets provided. Slide the assembled trim over the assembled panel set.

Figure 12.5

Install the new grille by reversing removal instructions.

Note: Clean glass and gold or nickel with glass cleaner and a soft cloth, wiping off all fingerprints prior to first fire to prevent permanent staining.

G. Panel Set Installation

Included in kit: (2) Angle Brackets and set screws; (1) 3 piece Trim; (2) Side Panels; (1) Top Panel; (1) Switch plug; and (8) screws.

Tools required: Philips head screwdriver.

Note: Remove the door from the insert before beginning the panel installation.

Assemble the panel top to the panel sides with the screws provided.

BACK OF TOP PANEL

SCREWS

BACK OF SIDE PANEL

Figure 12.6

Figure 12.7

Slide the panel/trim down over the face of the unit, behind the top, aligning the holes in the upper and lower, right and left corners, and secure the panel and trim set to the appliance with the attachment screws using four screws, two per side.

SCREWS

Figure 12.8

Determine your desired placement of the rocker switch.

1If you wish to place it on the control panel in the "Main Burner" opening: Disconnect the "ON/OFF" switch from the low voltage wire leads. Pull the wires through the control panel, attach the wires to the "ON/OFF" rocker switch and push the rocker switch into the "Main Burner opening on control panel. Place the plug provided in empty opening on the panel and trim.

OR

2.If you wish to place it on the side of appliance in the knock out provided on the panel and trim: Carefully reposition the wiring beneath the firebox to the RIGHT side of appliance. Disconnect the "ON/OFF" switch from the low voltage wire leads. Pull the wires through the knockout plate on the panel and trim, attach the wires to the "ON/OFF" rocker switch and push the rocker switch into the opening on the panel and trim. Place plug provided with panel set in empty switch location.

Install the power cord restraint found in the appliance com- ponent bag. (Cord is shipped exiting the right side of the appliance, but can be routed in either direction.) A notch will be needed in the trim piece for the cord restraint.

Slide the appliance back until the panel is tight to the fireplace.

30

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

Image 30
Contents Model What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Thermostats and Wall Switches Decorative Doors, Fronts and SurroundsFor Your Safety Read Before Lighting Standing Pilot IgnitionFrequently Asked Questions After Appliance is LitMaintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure Mantel and Wall Projections HearthTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance Factory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalConverting to LP Gas Gas InformationFuel Conversion Screws Nuts Holding Burner PANValve Regulator Replacement Gas Pressure Gas ConnectionWire Size Max. Length Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationBlower Installation Tools required Powered Phillips head screwdriverIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Finishing Clearance to CombustiblesAppliance Setup Tools required Philips head screwdriver Grille InstallationPanel Set Installation Back of TOP Panel Screws Back of Side PanelEmber Placement Placement of EmbersBrick Installation Retaining TabsPositioning the Logs Rear Brick Retaining TabsAir Shutter Adjustment Air shutter is used to fine-tune the flame as necessaryRemoving Fixed Glass Assembly Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference Materials B. Vent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsPart number list on following Service Parts List StockedDepot Description Comments Part Number Thermocouple 200-2950 Thermopile 842-0250Contact Information Do not Discard this Manual

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.