Quadra-Fire 7008-115 Installing Vent Pipe and Appliance, Vent Limits, Venting Components

Page 19

8 Installing Vent Pipe and Appliance

A. Vent Limits

The abbreviations listed in this vent table key are used in the vent diagrams.

Description

Minimum Vertical Run Length 10 ft.

Maximum Vertical Run Length 40 ft.

Horizontal venting is NOT allowed.

Vertical terminations are measured to top of chimney.

This appliance is listed for use with LINK-DV systems and components only. It is permissible to extend venting above existing chimney (within specified maximum verti- cal limits) using SL-D series or Dura Vent GS series 4 in. x 6-5/8 in. gas direct-vent pipe. Connection is made us- ing DV-46DVA-GK. The vent must be terminated with the cap supplied with the LINK-series vent kit.

WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION! ALL vent specifications MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.

B. Venting Components

CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

The vertical vent termination system installed on this model includes:

Flexible vent pipe for exhaust air (included with vent kit).

One length of 3-inch flexible vent pipe for combustion air (included with vent kit).

One pipe-to-cap adaptor (included with vent kit).

One vertical termination cap (included with vent kit).

C. Connecting Vent Pipe

Reference instructions in the termination kit.

Install the 3-inch flexible vent pipe(s) down through the chimney.

Secure the exhaust flexible vent pipe to the exhaust collar on the transition assembly. See Figure 8.1.

Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate (see Figure 8.1). NOTE: The collar slide plate may be removed from appliance to aid installation.

EXHAUST

AIR VENT

PIPE

Figure 8.1

TERMINATION CAP

ADAPTOR

V=10 FT. (3 M) MINIMUM

40 FT. (12 M) MAXIMUM

INLET AIR

VENT PIPE

THIS OPTION SHOWS THE AIR INLET

TERMINATING IN THE CHIMNEY.

INSULATION

Note: Insulation is not included with the venting kit.

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

19

Image 19
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Warranty Conditions Limited Lifetime WarrantyListing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Decorative Doors, Fronts and Surrounds Fixed Glass AssemblyRemote Controls, Thermostats and Wall Switches Clear SpaceStanding Pilot Ignition For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum fireplace opening requirements are shown in Figure Hearth Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsPlacing, Securing and Leveling the Appli- ance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningScrews Nuts Holding Burner PAN Gas InformationFuel Conversion Converting to LP GasValve Regulator Replacement Gas Connection Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring Wire Size Max. LengthTools required Powered Phillips head screwdriver Blower InstallationIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Clearance to Combustibles FinishingAppliance Setup Back of TOP Panel Screws Back of Side Panel Grille InstallationPanel Set Installation Tools required Philips head screwdriverPlacement of Embers Ember PlacementRetaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsAir shutter is used to fine-tune the flame as necessary Air Shutter AdjustmentRemoving Fixed Glass Assembly Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits  B. Vent Kits ComponentsService Parts Log Set AssemblyPart number list on following Stocked Service Parts ListDepot Thermocouple 200-2950 Thermopile 842-0250 Description Comments Part NumberDo not Discard this Manual Contact Information

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.