Quadra-Fire 7008-115 owner manual Placing, Securing and Leveling the Appli- ance, Remote Control

Page 20

CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

Figure 8.2

Trim chimney top plate to minimize excess overhang or bend over flue tile (see Figure 8.2).

Place 3/8 inch bead of silicone (minimum of 300ºF continuous exposure rating) on flue tile top.

D.Placing, Securing and Leveling the Appli- ance

Attach surround. Follow instructions accompanying surround.

Install insert (with surround attached) into existing fireplace while pulling transition assembly forward.

Attach Transition Assembly to the appliance. Rotate Transition Assembly latches and lock with 7/16 inch wrench.

Install gas line into hole provided on insert side.

If applicable install remote control wires into insert side (see Section 8.E.).

Level the appliance from side to side and front to back. If necessary, attach the shipping brackets that were used to attach the unit to the pallet, to the rear of the appliance for use as levelling legs.

Position any excess flexible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten.

Install fiberglass insulation pieces to back face of surround.

Push insert so that surround becomes tight against face of fireplace.

WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte- gral grills on solid fuel burning fireplaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.

WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING! Risk of Explosion/Combustion Fumes! Connect vent sections per installation instructions.

Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.

Connect inlet air vent ONLY to inlet air collar on appliance and either the termination cap inlet air collar OR terminate within chimney.

DO NOT allow vent to sag below connection point to appliance.

TERMINATION CAP

ADAPTER

FLEX PIPE

TRANSITION ASSEMBLY

SHIPPING BRACKETS ATTACHED

TO REAR OF APPLIANCE FOR

USE AS LEVELING LEGS

Figure 8.3

E. Remote Control

The receiver for the remotes must be installed BETWEEN the base pan of the insert and the firebox of the wood- burning fireplace (see photo below).

EXISTING SIDE

REFRACTORY

REMOTE

RECEIVER

UNIT

EXISTING BOTTOM OF

FIREPLACE

Figure 8.4

20

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

Image 20
Contents Model What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Thermostats and Wall SwitchesClear Space Decorative Doors, Fronts and SurroundsFor Your Safety Read Before Lighting Standing Pilot IgnitionFrequently Asked Questions After Appliance is LitMaintenance and Service Maintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionLogs FireboxGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum fireplace opening requirements are shown in Figure Fireplace Size RequirementsMinimum Fireplace Opening Mantel and Wall Projections HearthTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Installing Adaptor and Termination Cap MasonryFactory Built Wood Burning Damper Flashing Kit OptionalGas Information Fuel ConversionConverting to LP Gas Screws Nuts Holding Burner PANValve Regulator Replacement Gas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringWire Size Max. Length Electrical InformationIncluded in kit Blower Blower InstallationTools required Powered Phillips head screwdriver = 1/4 in mm female spade = 1/4 in mm male spade Finishing Clearance to CombustiblesAppliance Setup Grille Installation Panel Set InstallationTools required Philips head screwdriver Back of TOP Panel Screws Back of Side PanelEmber Placement Placement of EmbersBrick Installation Retaining TabsPositioning the Logs Rear Brick Retaining TabsAir Shutter Adjustment Air shutter is used to fine-tune the flame as necessaryRemoving Fixed Glass Assembly Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference Materials B. Vent Kits Components Direct Vent Flex Liner KitsPart number list on following Log Set AssemblyService Parts Depot Service Parts ListStocked Description Comments Part Number Thermocouple 200-2950 Thermopile 842-0250Contact Information Do not Discard this Manual

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.