Quadra-Fire 7008-115 owner manual Table of Contents, User Guide

Page 3

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 4

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

B. Glass Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 6

E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 6

F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 6

G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 C. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 D. Decorative Doors, Fronts and Surrounds. . . . . . . . . . . . . . 8 E. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 F. Remote Controls, Thermostats and Wall Switches . . . . . . 8 G. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . 8 H. Standing Pilot Ignition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 I. After Appliance is Lit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 J. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 10

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 11 B. Maintenance Tasks-Service Technician . . . . . . . . . . . . . . 12

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 13

B. Design and Installation Considerations . . . . . . . . . . . . . . 14

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 14

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 14

5 Fireplace Size Requirements

A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . 15 B. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 16

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 17

7 Installation Preparation

A. Inspection and Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . 18 B. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 C. Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 D. Hearth or Hearth Extension . . . . . . . . . . . . . . . . . . . . . . . 18 E. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 18

F. Electrical Outlet Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

8 Installing Vent Pipe and Appliance

A. Vent Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

B. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

C. Connecting Vent Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

D. Placing, Securing and Leveling the Appliance . . . . . . . . . 20

E. Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

F. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 21

9 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 B. Converting to LP Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 C. Valve Regulator Replacement . . . . . . . . . . . . . . . . . . . . . 23 D. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 E. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 F. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 24

10 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

B. Standing Pilot Ignition System Wiring . . . . . . . . . . . . . . . 25

C. Blower Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

11 Finishing

A. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 28

12 Appliance Setup

A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 29

B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 29

C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

E. Door Crown Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 29

F. Grille Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

G. Panel Set Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

H. Ember Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

I. Brick Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

J. Positioning the Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

K. Air Shutter Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

L. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

13 Troubleshooting

A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . . . . 36

14 Reference Materials

A. Appliance Dimension Diagram

38

B. Vent Kits Components

39

 

C. Service Parts

40

 

D. Contact Information

43

 

= Contains updated information.

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

3

Image 3
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Warranty Conditions Limited Lifetime WarrantyListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Decorative Doors, Fronts and Surrounds Fixed Glass AssemblyRemote Controls, Thermostats and Wall Switches Clear SpaceStanding Pilot Ignition For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure Hearth Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsPlacing, Securing and Leveling the Appli- ance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningScrews Nuts Holding Burner PAN Gas InformationFuel Conversion Converting to LP GasValve Regulator Replacement Gas Connection Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring Wire Size Max. LengthBlower Installation Tools required Powered Phillips head screwdriverIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Clearance to Combustibles FinishingAppliance Setup Back of TOP Panel Screws Back of Side Panel Grille InstallationPanel Set Installation Tools required Philips head screwdriverPlacement of Embers Ember PlacementRetaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsAir shutter is used to fine-tune the flame as necessary Air Shutter AdjustmentRemoving Fixed Glass Assembly Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits  B. Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following Service Parts List StockedDepot Thermocouple 200-2950 Thermopile 842-0250 Description Comments Part NumberDo not Discard this Manual Contact Information

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.