D. Gas Pressure

Optimum appliance performance requires proper input pressures.

Gas line sizing requirements will be determined in ANSI Z221.3 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada.

Pressure requirements are:

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

4.5 in. w.c.

11.0 in. w.c.

Maximum inlet pressure

7.0 in. w.c.

14.0 in. w.c.

Manifold pressure

3.5 in. w.c.

10.0 in. w.c.

WARNING! Risk of Fire/Explosion! High pressure will damage valve. Low pressure may cause explosion.

Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

E. Gas Connection

Refer to Reference Section 15 for location of gas line access in appliance.

Gas line may be run through knockout(s) provided.

The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with non- combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes.

Pipe incoming gas line into valve compartment.

Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve.

WARNING! Risk of Fire/Explosion! Support control when attaching pipe to prevent bending gas line.

• A small amount of air will be in the gas supply lines.

WARNING! Risk of Fire/Explosion! Gas build-up during line purge could ignite.

Purge should be performed by technician certified by NFI or factory-trained.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loos- ened during shipping and handling.

WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory.

F. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce burner orifice 4% for each 1000 feet above 2000 feet.

In the CANADA: Reduce burner orifice 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

24

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

Image 24
Contents Model What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Fixed Glass Assembly Remote Controls, Thermostats and Wall SwitchesClear Space Decorative Doors, Fronts and SurroundsFor Your Safety Read Before Lighting Standing Pilot IgnitionFrequently Asked Questions After Appliance is LitMaintenance and Service Maintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionLogs FireboxGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure Mantel and Wall Projections HearthTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Installing Adaptor and Termination Cap MasonryFactory Built Wood Burning Damper Flashing Kit OptionalGas Information Fuel ConversionConverting to LP Gas Screws Nuts Holding Burner PANValve Regulator Replacement Gas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringWire Size Max. Length Electrical InformationBlower Installation Tools required Powered Phillips head screwdriverIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Finishing Clearance to CombustiblesAppliance Setup Grille Installation Panel Set InstallationTools required Philips head screwdriver Back of TOP Panel Screws Back of Side PanelEmber Placement Placement of EmbersBrick Installation Retaining TabsPositioning the Logs Rear Brick Retaining TabsAir Shutter Adjustment Air shutter is used to fine-tune the flame as necessaryRemoving Fixed Glass Assembly Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionAppliance Dimension Diagram Reference Materials B. Vent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsPart number list on following Service Parts List StockedDepot Description Comments Part Number Thermocouple 200-2950 Thermopile 842-0250Contact Information Do not Discard this Manual

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.