Quadra-Fire 7008-115 owner manual Troubleshooting, Symptom Possible Cause Corrective Action

Page 37

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. (Continued)

C. Valve.

Turn the valve knob to the ON position. Place the ON/

 

 

OFF switch in the ON position. Take a reading with a

 

 

millivolt meter at the thermopile terminals. The millivolt

 

 

meter should read greater than 125mV. If the reading

 

 

is acceptable, and if the burner does not come on, re-

 

 

place the gas valve.

 

 

 

 

D. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stop-

 

 

page.

 

 

 

 

E. Wall switch or wires.

Check the wall switch and wires for proper connec-

 

 

tions. Place the jumper wires across the terminals at

 

 

the wall switch. If the burner comes on, replace the

 

 

wall switch. If the wall switch is OK, place the jumper

 

 

wires across the wall switch wires at the gas valve. If

 

 

the burner comes on, the wires are faulty or connec-

 

 

tions are bad.

 

 

 

4. Frequent pilot outage

A. Pilot flame may be too high or too low, or blow-

Clean thermocouple and adjust the pilot flame for

problem.

ing out (high pressure), causing pilot safety to

proper flame impingement. Follow lighting instructions

 

drop out.

carefully.

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish

 

 

B. Improper gas inlet pressure.

Natural gas should be 5-14 in. w.c. LP should be 10-

while in operation.

 

14 in. w.c. Verify pressure with manometer.

 

 

 

 

 

 

C. Inner vent pipe leaking exhaust gases back

Check venting system for damage. Replace/repair im-

 

into the system.

properly assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace

 

 

fixed glass panel assembly.

 

 

 

 

E. Thermopile or thermocouple.

Replace pilot if necessary.

 

 

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris

 

 

or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the flame does not exces-

 

 

sively impinge on it. Refer to log instructions.

 

 

 

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set

 

 

point is correct for appliance/gas type. If unit has ad-

 

 

justable shutter, it may be necessary to increase shut-

 

 

ter opening.

 

 

 

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MA-

 

 

TERIAL SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

A. Insufficient oxygen being supplied.

Ensure that the vent cap is installed properly and free

and lifts off burner.

 

of debris. Ensure that the vent system joints are tight

 

 

and have no leaks.

 

 

Ensure that no debris has been placed at the base of,

 

 

or in the area of the air holes in the center of the base

 

 

pan beneath the burner.

 

 

Ensure that the glass is tightened properly on the unit,

 

 

particularly on top corners.

 

 

 

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

37

Image 37
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Warranty Conditions Limited Lifetime WarrantyListing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Thermostats and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors, Fronts and SurroundsStanding Pilot Ignition For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum fireplace opening requirements are shown in Figure Hearth Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Masonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationConverting to LP Gas Screws Nuts Holding Burner PANValve Regulator Replacement Gas Connection Gas PressureStanding Pilot Ignition System Wiring Wiring RequirementsWire Size Max. Length Electrical InformationTools required Powered Phillips head screwdriver Blower InstallationIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Clearance to Combustibles FinishingAppliance Setup Panel Set Installation Grille InstallationTools required Philips head screwdriver Back of TOP Panel Screws Back of Side PanelPlacement of Embers Ember PlacementRetaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsAir shutter is used to fine-tune the flame as necessary Air Shutter AdjustmentRemoving Fixed Glass Assembly Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits  B. Vent Kits ComponentsService Parts Log Set AssemblyPart number list on following Stocked Service Parts ListDepot Thermocouple 200-2950 Thermopile 842-0250 Description Comments Part NumberDo not Discard this Manual Contact Information

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.