Quadra-Fire 7008-115 owner manual For Your Safety Read Before Lighting, Standing Pilot Ignition

Page 9

H. Standing Pilot Ignition

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may

result causing property damage, personal injury or loss of life

A.This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

*Do not try to light any appliance.

*Do not touch any electric switch, do not use any phone in your building.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

STOP! Read the safety information above on this label.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Set the thermostat to the lowest setting (if applicable) and turn off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the switch at the control panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Disconnect the power from the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Open the door of the appliance. May need to remove face/front first.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Push in gas control knob slightly and turn clockwise

to the "OFF"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position. Do not force.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you smell gas, STOP! Follow "B" of the safety information above. If you don't smell gas go to the next step.

7.Push gas control knob in and turn counterclockwise to the pilot position. NOTE: Knob cannot be turned unless knob is pushed in slightly. Do not force.

8.PIEZO IGNITER: Press down on the gas control knob in pilot position and simultaneously press the piezo igniter.

(This may take many repetitions for lighting.)

ELECTRONIC IGNITER: If the unit is equipped with an electronic igniter it should begin sparking right away.

9.The pilot should be visible through the door opening.

10.After the pilot is lit, continue holding control knob down for approximately

30 seconds. Release the knob and it will pop back up. Pilot should remain lit.

MILLIVOLT

PILOT HOOD

THERMOCOUPLE

If it goes out, repeat steps 7 through 9.

GENERATOR

* If the knob does not pop up when released, stop and immediately call your

 

 

service technician or gas supplier.

 

 

* If the pilot will not stay lit after several tries, turn the gas control knob

 

 

clockwise

to "OFF" and call your service technician or gas supplier.

 

 

11. Reinstall door and face. Wait five minutes to allow pilot flame to stabilize and establish proper draft.

12.Push down and turn gas control knob counterclockwise to "ON".

13.Push burner rocker switch on the control panel to "ON". If thermostat is to be used, leave switch in "OFF" position and set the thermostat to desired setting.

14.Reconnect electrical power to appliance.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3. Push in gas control knob slightly and turn clockwise

to "OFF" position.

Quadra-FireHUDBAY-INS7008-115 Rev. o • 8/11

9

Image 9
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Warranty Conditions Limited Lifetime WarrantyListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Thermostats and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors, Fronts and SurroundsStanding Pilot Ignition For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure Hearth Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance Masonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationConverting to LP Gas Screws Nuts Holding Burner PANValve Regulator Replacement Gas Connection Gas PressureStanding Pilot Ignition System Wiring Wiring RequirementsWire Size Max. Length Electrical InformationBlower Installation Tools required Powered Phillips head screwdriverIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Clearance to Combustibles FinishingAppliance Setup Panel Set Installation Grille InstallationTools required Philips head screwdriver Back of TOP Panel Screws Back of Side PanelPlacement of Embers Ember PlacementRetaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsAir shutter is used to fine-tune the flame as necessary Air Shutter AdjustmentRemoving Fixed Glass Assembly Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits  B. Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following Service Parts List StockedDepot Thermocouple 200-2950 Thermopile 842-0250 Description Comments Part NumberDo not Discard this Manual Contact Information

7008-115 specifications

The Quadra-Fire 7008-115 is a powerful and efficient wood stove that combines advanced technology with a classic design. It is ideal for homeowners looking to embrace a sustainable heating solution while enjoying the aesthetic appeal of a traditional wood-burning appliance. Known for its outstanding performance, this stove is a great addition to any living space.

One of the standout features of the Quadra-Fire 7008-115 is its exceptional heating capacity. This model is designed to heat large areas efficiently, making it suitable for both residential and commercial applications. With a heating output that can reach up to 800 square feet or more, it easily warms an entire room, providing comfort during cold winter months. Its large firebox can accommodate logs up to 18 inches in length, allowing for longer burn times and reduced refueling frequency.

The stove incorporates Quadra-Fire’s patented Technology, which enhances combustion efficiency and minimizes emissions. This advanced system ensures that the wood burns cleanly and completely, producing more heat and less smoke. The stove features an air-wash system that keeps the glass door clean, allowing users to enjoy a clear view of the flickering flames while maintaining air quality within the home.

In terms of design, the Quadra-Fire 7008-115 boasts a sleek and elegant appearance that blends seamlessly with various interior styles. Its cast iron construction provides durability and longevity, ensuring that the stove can withstand high temperatures without compromising structural integrity. Available in multiple finishes, including classic black and other decorative options, it complements any décor.

Safety is a priority with the Quadra-Fire 7008-115. It is equipped with a built-in safety barrier to prevent accidental contact with hot surfaces. Additionally, the stove adheres to strict EPA emissions standards, making it an eco-friendly choice for the environmentally conscious consumer.

Installation is made simple with the Quadra-Fire 7008-115, as it can be vented both vertically and horizontally, providing versatile options for installation in various home layouts. This adaptability ensures that homeowners can integrate the stove into their existing spaces without extensive renovations.

In conclusion, the Quadra-Fire 7008-115 is a top-tier wood stove that offers a blend of efficiency, safety, and classic design. With its advanced technologies and robust heating capabilities, it stands out as a reliable heating solution for those looking to enjoy the warmth and ambiance of a wood fire.