Quadra-Fire QVI-30FB-S owner manual Maintaining and Servicing Appliance, Maintenance Tasks

Page 32

14 Maintaining and Servicing Appliance

A. Maintenance Tasks

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance checkup at the beginning of each heating season.

WARNING

Risk of injury or property damage.

Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After servicing:

Replace any screen or barrier that was removed.

Reseal and reinstall any venting removed for servicing.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts.

Condition of glass, glass assembly and glass seal.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Burner air shutter adjustment

Gas connections and fittings.

Obstructions of termination cap.

Clean:

• Glass

Air passageways, grilles, control compartment

Burner, burner ports

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

CAUTION

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hours operation.

Longer operation without cleaning glass may cause a permanent white film on glass.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when hot.

Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

Remove and clean glass assembly.

Replace glass assembly and operate appliance for additional 12 hours.

Refer to maintenance instructions.

WARNING

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

32

Quadra-FireQVI-30FB-S2020-910 Rev. H • 6/09

Image 32
Contents Models Commonwealth of MassachusettsHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededInspect Firebox Fireplace Size Requirements Minimum Fireplace OpeningMinimum fireplace opening requirements are shown in Figure LocationClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesFire Risk Asphyxiation Risk Foot minimum in snow regionsVent Information and Diagrams Vent Table KeyHorizontal Venting Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Reference instructions in the termination kitPlacing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap MasonryFactory Built Wood Burning Damper Flashing Kit OptionalRefer to for location of gas line access in ap- pliance Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Wiring the Appliance ON/OFF SwitchElectrical Information Appliance RequirementsJunction Box Installation Installation for Fan OptionalOptional Accessories Shock hazardFAN Junction BOX Mantel Projections Installing Trim SurroundsFinishing Appliance Setup Clean the ApplianceAccessories Ember PlacementPositioning the Logs Log Assembly LOGS-QVI30FBLog Placement Quadra-Fire QVI-30FB-S 2020-910 Rev. H 6/09 Quadra-Fire QVI-30FB-S 2020-910 Rev. H 6/09 Glass Assembly Air Shutter SettingRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceThis appliance has a Standing Pilot Ignition Before operating this appliance have a qualified technicianLighting Appliance Standing Pilot IgnitionInitial Break-in Procedure Check Pilot Flame AppearanceAfter Appliance is Lit Do not operate appliance with glass door removedFrequently Asked Questions Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Maximum flame impingement. Follow lighting instruc TroubleshootingSymptom Possible Cause Corrective Action Risk of injury or property damage Maintenance TasksMaintaining and Servicing Appliance Inspect Maintenance Tasks Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsLog Set Assembly Service PartsBeginning Manufacturing Date Oct Ending Manufacturing DateAt Depot Service Parts ListStocked Valve Assembly Be ordered from an authorized dealerLimited Lifetime Warranty Limited Lifetime Warranty Contact Information Important operating