Quadra-Fire QVI-30FB-S Vent Information and Diagrams, Vent Table Key, Horizontal Venting

Page 10

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

VMIN

Minimum Vertical Run Length 14 ft.

VMAX

Maximum Vertical Run Length 50 ft.

B. Horizontal Venting

Horizontal venting is NOT allowed.

C. Measuring Standards

Vertical measurements listed in the vent diagram (Figure

5.1) were made using the following standard:

• Vertical terminations are measured to top of chimney.

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

Vent this appliance directly outside.

Use separate vent system for this appliance.

CAUTION

ALL vent specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Note: To achieve optimum performance of insert, minimize or avoid bends in exhaust vent pipe.

TERMINATION

CAP

ADAPTOR

EXHAUST COLLAR

INLET AIR COLLAR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM 50 FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

Figure 5.1

10

Quadra-FireQVI-30FB-S2020-910 Rev. H • 6/09

Image 10
Contents Models Commonwealth of MassachusettsHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox Minimum fireplace opening requirements are shown in Figure Fireplace Size RequirementsMinimum Fireplace Opening LocationClearances Clearances to Mantels or other Combustibles above ApplianceFire Risk Asphyxiation Risk Termination LocationsVent Termination Minimum Clearances Foot minimum in snow regionsHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Reference instructions in the termination kitPlacing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalFuel Conversions Gas Connection Refer to for location of gas line access in ap- plianceGas Information Gas PressuresHigh Altitude Installations Electrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsOptional Accessories Junction Box InstallationInstallation for Fan Optional Shock hazardFAN Junction BOX Finishing Installing Trim SurroundsMantel Projections Accessories Appliance SetupClean the Appliance Ember PlacementLog Placement Log Assembly LOGS-QVI30FBPositioning the Logs Quadra-Fire QVI-30FB-S 2020-910 Rev. H 6/09 Quadra-Fire QVI-30FB-S 2020-910 Rev. H 6/09 Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyThis appliance has a Standing Pilot Ignition Operating InstructionsBefore Lighting Appliance Before operating this appliance have a qualified technicianLighting Appliance Standing Pilot IgnitionAfter Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Do not operate appliance with glass door removedFrequently Asked Questions Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaximum flame impingement. Follow lighting instruc Maintaining and Servicing Appliance Maintenance TasksRisk of injury or property damage Inspect Maintenance Tasks Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsBeginning Manufacturing Date Oct Log Set AssemblyService Parts Ending Manufacturing DateStocked Service Parts ListAt Depot Valve Assembly Be ordered from an authorized dealerLimited Lifetime Warranty Limited Lifetime Warranty Contact Information Important operating