Napoleon Fireplaces GDS 50-P, GDS 50-N manual Stove Vent Connection, Mobile Home Installation

Page 11
" /4 -3 5

STOVE VENT CONNECTION

1. Attach the ad-

FIGURE 21

justable

pipe

to

 

the last section of

#8x1/2"

rigid

piping. Se-

SELF DRILLING

SCREWS

cure with screws

2" OVERLAP

and seal.

 

 

HI-TEMP

2. Install the 4"

SEALANT

aluminum flexible

 

liner to the stove.

ON/OFF

Secure

with

3

SWITCH

screws

and

 

flat

 

washers. Seal the

VARIABLE

joint

and screw

SPEED SWITCH

holes

using

Mill

 

Pac

high

tem-

 

perature sealant not supplied.

11

MOBILE HOME INSTALLATION

In Canada, mobile home installation may be vented hori- zontally or vertically. In the United States, it may only be installed vertically. See "Vertical Venting" or "Horizontal Air Terminal Installation" for installation.

The fireplace is equipped with two 5/16" diameter holes located near each corner of the base. For mobile home installations, the fireplace must be fastened in place. Use #10 screws, inserted through the holes in the base to se- cure. It is recommended that the fireplace be secured in all installations.

3.Run a bead of red RTV high tem- perature sealant around the inside of the air intake

collar. Pull the adjustable pipe intake collar.

1

4

 

 

 

 

-

 

 

 

 

5/

 

 

 

 

3

 

 

 

 

2

 

 

 

 

"

a minimum 2" into the air

Ensure that the sealant is not visible on the exte- rior pipes once installation is completed. An op- tional decorative brass band is available for this use. (Standard with a GD175 kit). In the event that the venting must be disassembled, care must be taken to reseal the venting.

Continue with "Gas Installation" Page 14

W415-0098 / C / 04.19.06

Image 11
Contents GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information GDS50 and GS50 Location & ClearancesGAS Stove Direct Vent Specifics Model GDS50Venting Lengths AIR Terminal Locations AIR Terminal Locations Horizontal Offset Installation ExampleSpecial Installation Example Stove Pipe Must Rise ¼ PER Foot of RUN Horizontal Installation Vertical InstallationWall and Ceiling Protection Vertical Venting Installation Horizontal Venting InstallationStove Vent Connection Mobile Home InstallationAdding Vent Sections Chimney InstallationInstalling B Vent Vent Specifics Model GS50TWO Screws Must be RE-SECURED. Figure Installing Flashing Storm CollarVent Adaptations Combustion AIRVent Model GS50 GAS InstallationGAS Installation Vent Model GS50 only Direct Vent Model GDS50Fire Viewing Door Side Door Valve Control Door Door Opening and Closing Trivet InstallationFinishing LOG Placement Operating Instructions Operation / MaintenanceTurbo Burner Operation Maintenance Spill SwitchFor Your Safety Read Before Lighting Replacement Blower Installation Front Burner Rear Burner AdjustmentsPilot Burner Adjustment Venturi AdjustmentGD112 Flat Roof ReplacementsGD175 Wall Terminal KIT GD180 PeriscopeAtte Symptom Problem Test Solution Trouble Shooting GuideModel GDS50 only