ADJUSTMENTS
PILOT BURNER ADJUSTMENT
Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Replace the pilot screw cap.
VENTURI ADJUSTMENT
To access the venturi, remove the screw securing each burner to the burner pan; slide to the right, lift up and out. For the air shutter settings, see the chart below.
FIGURE 36
TOLIP
PILOT SCREW
FIGURE 37
OL
HI
N O
FO
F
OT | P |
LI |
|
|
|
|
|
| FRONT BURNER | REAR BURNER |
| NG | ¼ | ½ |
| LP | ¼ | ½ |
|
|
|
|
Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab- lished.
FIGURE 38
Air shutter adjustment must only be done by a qualified gas installer!