B-VENT SPECIFICS - MODEL GS50
CHIMNEY INSTALLATION
Three types of chimney systems may be used with this stove:
FIGURE 22
A CHIMNEY VENTING THIS STOVE SHALL NOT VENT
ANY SOLID FUEL BURNING APPLIANCE.
ALL HORIZONTAL RUNS MUST HAVE
A 1/4 INCH RISE PER FOOT.
FIGURE 23
ADAPTER
SPILL
SWITCH
INSTALLING 'B' VENT:
Follow the instructions for "Wall and Ceiling Protection".
ADAPTER INSTALLATION FIGURE 23
1.Remove the spill switch bracket from the rear of the adapter.
2.Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches.
3.Bring the wires through the lower hole in the adapter and out the spill switch opening. To pass the wires through the hole more easily, temporarily tape the two terminals to- gether.
4.With the spill switch opening aligned to the back of the stove, take hold of the adaptor base and push the crimped edge into the stove flue collar.
5.Connect the wire terminals to the spill switch and re- secure the bracket.
For aesthetics, the adapter has been designed to accept a standard matte black 7" stove pipe and the Napoleon decorative brass band (standard with the GS150KT). Both are available from your Napoleon dealer.
ADDING VENT SECTIONS
For ease of assembly, a 7" telescoping stove pipe may be installed over the 4" vent connection of the adapter. Add vent sections, twist locking (clockwise) securely, to the required height. The vent should ex- tend, at least, 3 feet above its point of contact with the roof and, at least, 2 feet higher than any wall, roof or building within 10 feet. FIGURE 24. (This is a guide- line only; local venting codes should be followed which may differ in height and clearance require- ments.)
FIGURE 24